Use this profile to configure the Unable to show "metadata-from": No such page "_space_variables"
active profile name using the built-in standard profiles.
This feature is only applicable when four or more vCPUs are configured.
For Unable to show "metadata-from": No such page "_space_variables"
(D-SBC), the profiles are automatically configured based on the personality. These profiles prevent reboot during instantiation.
SBC SWe Cloud Automatic Configuration
| |
---|
I-SBC | default |
S-SBC | standard_signaling_profile |
M-SBC | standard_msbc_profile |
Command Syntax
% set system sweActiveProfile name <profile name>
default
standard_callmix_profile
standard_msbc_profile
standard_passthrough_profile
standard_signaling_profile
standard_transcoding_profile
Command Parameters
SBC SWe Active Profile Parameters Profiles
| |
---|
default | By default, non-cloud instances use the default profile. This profile retains the SBC SWe behavior of earlier release (5.0.x and 5.1.x releases), where signaling and media vCPUs overlap. |
standard_callmix_profile | This profile supports a call mix containing a combination of 90% pass-through and 10% transcoding. |
standard_msbc_profile | This profile gets auto-configured on the cloud-based M-SBC instance.This profile utilizes the vCPUs for pass-through calls. |
standard_passthrough_profile | This profile utilizes the vCPUs primarily for pass-through calls. |
standard_signaling_profile | This profile utilizes the vCPUs for signaling (direct media) calls and it is auto-configured on the cloud-based S-SBC instance. |
standard_transcoding_profile | This profile utilizes the vCPUs for transcoding calls. |