This object controls donor switch service.
To View and Edit Donor Switch Service
On SBC main screen, go to Configuration > Profile Management > Category: Signaling Profiles > Signaling Profile > Egress > Donor Switch Service.
Select the desired Signaling Profile from the drop-down list to view its respective Donor Switch Service parameters.
The Donor Switch Service window is displayed.
Signaling Profiles - Signaling Profile - Egrees - Donor Switch Service
The following fields are displayed:
Signaling Profile - Egress - Donor Switch Service parameters
Parameter | Description |
---|
Create Called Directory Number In Egress Signal | This flag is applicable only when the Donor Switch Service has been executed. When this flag is enabled, the egress signal contains the Called Directory Number (Dialed Number) and the Called Party Number (NRN). |
Generate Redirection Count | When this flag is enabled, the SBC adds the redirection counter to the egress IAM. This parameter is for backward compatibility with legacy systems. |
Skip Redirection After Number Translations | When this flag is enabled, PSX skips looking into several tables for redirection once number translation is complete for Donor switch service. |
Undo Donor Switch Service | When this flag is enabled, even though the Donor Switch Service is executed, the egress signal contains the Called Party Number containing the Dialed Number. |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.