The following procedure describes how to use the Windows PC/terminal to connect the 

Unable to show "metadata-from": No such page "_space_variables"
serial port and assign it an IP address.

Procedure

  1. Connect one end of the supplied serial cable (DSUB 9-Pin Female to DSUB 9-Pin Male) to the SBC DB9 serial port and the other end to the serial port of your PC.

  2. Use the following serial port settings of PC.
    . Baud:38400
    . Data bits:8
    . Stop bits:1
    . Parity:None
    . Flow Control:None

  3. Login to the BMC using default credentials:
    At the prompt enter:
    Username: linuxadmin
    Password: <password>

  4. Switch User to 'root' using the command: su -
    Enter the 'root' access password.

  5. At the 'root' level, execute the bmcInit.sh command. Assign the BMC management IP address, netmask, default gateway and NTP time server IP address.

    Example:

    # sh bmcInit.sh
    *************************************************************
    ***                BMC Initialization                     ***
    *************************************************************
    Enter BMC management IP (aaa.bbb.ccc.ddd)     : 10.2.12.181
    Enter BMC management netmask (aaa.bbb.ccc.ddd): 255.255.255.0
    Enter default gateway IP (aaa.bbb.ccc.ddd)    : 10.2.12.1
    Enter NTP time server IP (aaa.bbb.ccc.ddd)    : 10.1.1.2
    
    Enter advanced configuration? <y/n>:n
    
    Note: The advanced configuration is used exclusively to configure static routes. For this installation example, enter "n".
    
    Verify your entries....
    bmcIpAddr       = 10.2.12.181
    bmcNetmask      = 255.255.255.0
    gatewayIpaddr   = 10.2.12.1
    ntpServerIpaddr = 10.1.1.2
    
    Ok to apply configuration? <y/N>:y
    
    Restarting NTP and network services ....
    Setting up IP spoofing protection: rp_filter.
    Reconfiguratoin network interfaces...done.
    Restarting NTP server: ntpd... done.
    Note: Reboot the BMC after completing the process.
  6. Connect the Field Service port of SBC to the Ethernet router and access the BMC over the network.

 