Specifies the MFR2 digit generation attributes.

To View and Edit Mfr2Generate

On SBC main screen, go to Configuration > Profile Management > Category: Digit Profiles > Digit Profiles > Mfr2Generate.

Select the desired Digit Profile from the drop-down list to view its respective Mfr2Generate parameters.

The Mfr2Generate window is displayed.

Profile Management - Digit Profiles - Mfr2Generate

The following fields are displayed:

Dtmf Mfr2Generate Parameters

Parameter Description
PowerDigit generation power level (in dBm). (range: -50 to +3 / default = -7).
MakeDuration (in milliseconds) of generated digits. (range: 0-8000 / default = 150).
BreakSilence duration (in milliseconds) between generated digits (range: 0-8000 / default = 150).
Pre Pulse DelayDelay (in milliseconds) between the end of last compelled signal and the start of backward pulsed signal. (range: 0-8000 / default = 100).
Max Fwd On DurationMaximum amount of time (in milliseconds) a forward signal is sent. (range: 100-60000 / default = 15000).
Max Fwd Off DurationMaximum amount of time (in milliseconds) between the removal of a forward signal and the sending of the next forward signal. (range: 100-60000 / default = 27000).
Final Digit DelayMinimum interval (in milliseconds) after sending last message to apply answer line signal in the backward direction. (range: 0-8000 / default = 50).

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 