Use this object to view and/or edit ingress Trunk group for the selected Signaling Profile.

To View and Edit Ingress

On SBC main screen, go to Configuration > System Provisioning > Category: Call Routing > Profiles > Signaling Profile > Ingress.

The Signaling - Ingress can be checked for specific Signaling Profile. Choose the desired Signaling Profile from the drop-down box.

Call Routing - Profiles - Signaling Profile - Ingress Main Window

The Ingress window is displayed.

Call Routing - Profiles - Signaling Profile - Ingress Edit Window

The following fields are displayed:

Call Routing - Profiles - Signaling Profile - Ingress Parameters


Parameter


Description

Disallow Missing Calling Number

When enabled, the Calling Party Validation feature is enabled, which disallows calls that do not contain a calling party number.

  • disable (default)
  • enable
Disallow Tns And Trunk Group Originating Carrier Match

When enabled, disallows the calls when the TNS parameter matches the originating carrier assigned to the ingress trunk group.

  • disable (default)
  • enable
Disallow Without Billing Number

When enabled, disallows the calls to be completed if there is no billing number.

  • disable (default)
  • enable
Disallow Without Olip

When enabled, all calls without OLIP will be rejected.

  • disable (default)
  • enable
Discard Redirection Backward Information

When enabled, the PSX informs the SBC to discard the backward redirection information parameter received in REL.

  • disable (default)
  • enable
Discard Redirection Count For Release

When enabled, the PSX informs the SBC to discard the redirection count parameter.

  • disable
  • enable (default)
Dont Generate Exit Message

When enabled, controls the generation of the EXM message on the associated ingress trunk group.

  • disable (default)
  • enable
Enable Redirection Capability

When enabled, redirection capabilities are enabled on the ingress trunk group.

  • disable (default)
  • enable
Fe Param In Short Form

When enabled, the SBC generates the FE parameter in the short form.

  • disable (default)
  • enable
Generate Charge Message

When enabled, the PSX generates charge band information for billing purposes and sends the information to the SBC in policy responses on a per-route basis.

  • disable (default)
  • enable
Generate Cpg For Call Forward Notify

When enabled, PSX instructs the SBC to send CPGs (call progress messages) in a backward direction, releasing the ingress leg.

  • disable (default)
  • enable
Perform Calling Party Screening

When enabled, the PSX performs calling party screening and retrieves the configured member status from the subscriber table.

  • disable
  • enable (default)
Perform Cpc Screening

When enabled, the PSX will perform Calling Party Category (CPC) screening to determine if this call should be restricted based on the received CPC.

  • disable (default)
  • enable
Propagate Egress Channel Info

When enabled, it propagates the egress PSTN channel information in SIP 18x/200 or Final Response messages returned by a SBC to this SIP Server (via the "chan" parameter in the To: field).

  • disable (default)
  • enable
Propagate Fe Param

When enabled, it controls the propagation of the FE parameter in the backward directions for call arriving on the associated trunk group.

  • disable (default)
  • enable
Separate Alert From Progress For Sip Interworking

When enabled, controls the propagation of the FE parameter in the backward directions for call arriving on the associated trunk group.

  • disable (default)
  • enable
Treat Cic0000As No Cic

When enabled, calls arriving with carrier code 0000 are treated as if there is no carrier code.

  • disable (default)
  • enable
Use Isup Rel On Sus Timer

When enabled, and the called party goes on hook, the SBC starts the SUS (Suspend) timer and releases the call when the SUS timer expires.

  • disable (default)
  • enable
Validate Gap Type Ported Number

When enabled, the SoftSwitch verifies that the Generic Address Parameter (GAP) type field is set to Ported Number.

  • disable (default)
  • enable

Make the required changes to the required fields and click Save to save the changes.

 