Configure the
Spacevars | |
---|---|
|
...
|
Use the following procedure to configure the
Spacevars | ||
---|---|---|
|
- Access a compatible web browser.
- In the browser, enter the IP address of the SBC Edge in the URL address bar. The Welcome to Ribbon screen is displayed.
- Review the Pre-Login message.
- Enter the administrator User Name and Password configured during initial setup.
- If the Acknowledge Pre-Login Message checkbox is displayed, click on it to acknowledge you have reviewed the pre-login information above. After initial login, you can enable and disable this checkbox via the Global Security Options. By default, this checkbox is configured as disabled.
Click Login. The main screen provides all WebUI functions, including tabbed options, menu tree, device name, and the last login date and time of the system.
Select Settings > System > Node-Level Settings.
Caption 0 Figure 1 SBC 1000/2000 EdgeView in Node-Level Settings Screen - Enabled Note title Caution When you enter the EdgeView Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the
cannot connect to the EdgeView.Spacevars 0 product3 Caption 0 Figure 1 SBC SWe Lite EdgeView in Node-Level Settings Screen - Enabled Use the following table to configure the EdgeView panel.
Caption 0 Table 1 EdgeView Parameters
ofParameter Description EdgeView Configure this field to enable or disable the EdgeView SCC.
- No (default) - The EdgeView is disabled.
- Yes - The EdgeView is enabled.
EdgeView Address Configure this field with the IP address or FQDN of the EdgeView.
Note: This field applies only when the EdgeView field is set to Yes.
EdgeView Management ID Caution: When you enter the EdgeView Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the
cannot connect to the EdgeView.Spacevars 0 product3 Configure this field with the Management ID
for the EdgeView.
Note: This field applies only to the
. TheSpacevars 0 product3
automatically sends the MAC address to the EdgeView.Spacevars 0 longproduct Note: This field applies only when the EdgeView field is set to Yes.
EdgeView Connection The status of the SBC’s connection to the EdgeView. This status may be one of the following:
- Down
- Up
Note: This field applies only when the EdgeView field is set to Yes.
EdgeView Tunnel Status The status of the HTTPS tunnel from the EdgeView to the SBC. This status may be one of the following:
- Down
- Up
Note: This field applies only when the EdgeView field is set to Yes.
EdgeView C2E License The status of the EdgeView Cloud to Edge Licensing on the SBC. This status may be one of the following:
- False
- True
Note: This field applies only to the
.Spacevars 0 product3 Note: This field applies only when the EdgeView field is set to Yes.
- Click Apply.