Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH2UserResourceIdentifier{userKey=8a00a0c85b2726c2015b58aa779d0003, userName='null'}
AUTH1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb41059c, userName='null'}
JIRAIDAUTHCHOR-4035
REV5UserResourceIdentifier{userKey=8a00a0c85b2726c2015b58aa779d0003, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a0c85b2726c2015b58aa779d0003, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a0c85c46b657015d505775a80024, userName='null'}
REV4UserResourceIdentifier{userKey=8a00a0c86062358001607e0702a30014, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cc7d083d, userName='null'}
REV2UserResourceIdentifier{userKey=8a00a0c86d7a8a62016d81ab2a4a0001, userName='null'}

Excerpt Include
Configuring for EdgeView during Initial Setup
Configuring for EdgeView during Initial Setup
nopaneltrue

...

Configure the 
Spacevars
0

...

product
for EdgeView at Node-level

Use the following procedure to configure the 

Spacevars
0product3product
for EdgeView at the node-level.

  1. Access a compatible web browser.
  2. In the browser, enter the IP address of the SBC Edge in the URL address bar. The Welcome to Ribbon screen is displayed.
  3. Review the Pre-Login message.
  4. Enter the administrator User Name and Password configured during initial setup.
  5. If the Acknowledge Pre-Login Message checkbox is displayed, click on it to acknowledge you have reviewed the pre-login information above. After initial login, you can enable and disable this checkbox via the Global Security Options. By default, this checkbox is configured as disabled.
  6. Click Login. The main screen provides all WebUI functions, including tabbed options, menu tree, device name, and the last login date and time of the system.

  7. Select Settings > System > Node-Level Settings.

    Caption
    0Figure
    1SBC 1000/2000 EdgeView in Node-Level Settings Screen - Enabled

    Image Added


    Note
    titleCaution

    When you enter the EdgeView Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the

    Spacevars
    0product3
    cannot connect to the EdgeView.


    Caption
    0Figure
    1SBC SWe Lite EdgeView in Node-Level Settings Screen - Enabled


  8. Use the following table to configure the EdgeView panel.

    Caption
    0Table
    1EdgeView Parameters


    ParameterDescription
    EdgeView

    Configure this field to enable or disable the EdgeView SCC.

    • No (default) - The EdgeView is disabled.
    • Yes - The EdgeView is enabled.
    EdgeView Address

    Configure this field with the IP address or FQDN of the EdgeView.

    Note: This field applies only when the EdgeView field is set to Yes.

    EdgeView Management ID

    Caution: When you enter the EdgeView Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the 

    Spacevars
    0product3
    cannot connect to the EdgeView.

    Configure this field with the Management ID

    of

    for the EdgeView.

    Note: This field applies only to the

    Spacevars
    0product3
    . The 
    Spacevars
    0longproduct
    automatically sends the MAC address to the EdgeView.

    Note: This field applies only when the EdgeView field is set to Yes.

    EdgeView Connection

    The status of the SBC’s connection to the EdgeView. This status may be one of the following:

    • Down
    • Up

    Note: This field applies only when the EdgeView field is set to Yes.

    EdgeView Tunnel Status

    The status of the HTTPS tunnel from the EdgeView to the SBC. This status may be one of the following:

    • Down
    • Up

    Note: This field applies only when the EdgeView field is set to Yes.

    EdgeView C2E License

    The status of the EdgeView Cloud to Edge Licensing on the SBC. This status may be one of the following:

    • False
    • True

    Note: This field applies only to the

    Spacevars
    0product3
    .

    Note: This field applies only when the EdgeView field is set to Yes.



  9. Click Apply.