This section describes the different methods to upgrade the
Spacevars | ||
---|---|---|
|
When an
Spacevars | ||
---|---|---|
|
Prerequisities
Prior to performing an upgrade on the
Spacevars | ||
---|---|---|
|
Spacevars | ||
---|---|---|
|
(in general)
:- Before upgrading the ConnexIP OS, firmware, and the
application, you must first save the configuration in case you encounter any issues during the upgrade.Spacevars 0 product - This will allow you to restore the system and continue if any issue arises during the upgrade process.
- Refer to Saving the SBC Configuration and Restoring SBC Configuration.
Before upgrading the application, upgrade the SBC firmware to the latest version on both the active and standby SBCs for an HA pair.
- Refer to the target Release Note for the latest firmware version.
- Upgrade the firmware using Upgrading the BMC and BIOS Firmware procedure.
Spacevars | ||
---|---|---|
|
Increase the memory to the larger of:
- the minimum memory required for the release.
or - the memory required for the desired session capacity.
Info title Note The performance/capacity of the
is impacted by the amount of memory assigned to the VM. Review SBC SWe Performance Metrics to see the memory requirements for the current release plus a procedure to upgrade memory, if required. Complete the procedure to upgrade memory prior to performing the upgrade.Spacevars 0 product2 - the minimum memory required for the release.
- Ensure the
memory reservation meets the requirements for the current release. Refer to SBC SWe Performance Metrics.Spacevars 0 product2 - Check the minimum disk space requirements:
Multiexcerpt include MultiExcerptName disk_space_requirement PageWithExcerpt _Disk_Space_Requirement_SWe_Cloud_Upgrades
Info | ||
---|---|---|
| ||
To recover from a mismatch in session estimates in an HA pair, refer to Recovering from Default Indices in 1:1 HA SBC SWe, if applicable. |
Info | ||
---|---|---|
| ||
The E1000E network interface type is unsupported in VMware. |
Span |
---|
Live Software Upgrade (LSWU)
LSWU allows a user users to upgrade the
Spacevars | ||
---|---|---|
|
Spacevars | ||
---|---|---|
|
Spacevars | ||
---|---|---|
|
Non-Live Software Upgrade (Non-LSWU)
The non-LSWU upgrade process requires taking the SBC system offline to perform an application upgrade. This refers to upgrading the
Spacevars | ||
---|---|---|
|
Info | ||
---|---|---|
| ||
Once the upgrade is complete, rediscover the SBC from the EMS/RAMP, if present, and edit any modified attributes that may have been modified post-upgrade. Attributes are listed under the EMS page at: .If the SBC is configured and registered in RAMP, the connection may be lost after the first server upgrade. RAMP may take time to show the SBC as Registered again until both servers are completely upgraded. |
Notes for Performing Upgrade from 11.1.0x Release
On a
7000 setup, the active node takes more than expected the time for the services to come up after an upgrade to V12.00.00R000 from 11.1.0x. Before performing an upgrade from 11.1.0x, apply the following steps: Spacevars 0 product
- Confirm that the cnixpmadmin password is not default by running the following command as root on the active and standby nodes:
$ENCRYPTED_STORE_SH cnxipmadmin
NOTE: The command must not show the default password "Cnx1PmAdm1n" - If the password is still default, randomize the password by running the following command as root on the active node:
$CHANGE_DEFAULT_PASSWDS_SH - Check the cnxipmadmin password is updated to random on the active and standby node by running the following command:
$ENCRYPTED_STORE_SH cnxipmadmin