Create a new SIP Message Rule Tables. This entry will only activate on INVITE messages.
Panel |
---|
|
Caption |
---|
0 | Figure |
---|
1 | Create New SIP Message Rule Tables |
---|
| Image Modified |
|
Create a Message Rule Table entry. As Proxy-Authorization is not a pre-defined Header Name, you will need to type Proxy-Authorization manually into the field.
Panel |
---|
|
Caption |
---|
0 | Figure |
---|
1 | Create Message Rule Table Entry |
---|
| Image Modified |
|
In the Message Rule Table entry, click the Add/Edit button and enter the Message Field values as shown. This regex will match the Proxy-Authorization header and remove the <> (brackets) from the uri parameter.
Panel |
---|
|
Caption |
---|
0 | Figure |
---|
1 | Edit Message Field |
---|
| Image Modified |
|
Apply the SIP Message Manipulation to the Output Message Manipulation on the desired egress Signaling Group.
Panel |
---|
|
Caption |
---|
0 | Figure |
---|
1 | Apply SIP Message Manipulation |
---|
| Image Modified |
|
...