Displays the list of flag parameters for redirecting capability flags.

To View and Edit Flags

On SBC main screen, go to Configuration > Profile Management > Category: Signaling Profiles > Signaling Profile > Egress >Redirection Capability Flags > Flags.

Select the desired Signaling Profile from the drop-down list to view its respective Redirection Capability Flags parameters.

Note

This option displays parameters only when Redirection Capability Flags options is enabled.

The Flags window is displayed.

Caption
0Figure
1Configuration - Profile Management - Signaling profile - egress - Redirection capability Flags - Flags

The following fields are displayed:

Caption
0Table
1Signaling Profile - Egress - Redirection Capability Flags - Flags parameters
ParameterDescription
Check Carrier Code Combination

When enabled, SBC matches the carrier code in the call against configured carrier codes in the Carrier Code Combination Profile. The options are:

  • Enable
  • Disable (default)
Check Ingress Trunk Grp Redirection Capability

When enabled, SBC checks for Ingress Trunk Group redirection capabilities. The options are:

  • Enable
  • Disable (default)
Check Number Control Profile For Received Called Number

 When enabled, SBC checks the Number Control Profile for a match on the received called number. The options are:

  • Enable
  • Disable (default)
Check Received Redirection Params

 When enabled, SBC checks for both the redirection capability parameter and the redirection information parameter. The options are:

  • Enable
  • Disable (default)
Check Redirection Cap of Number Used for Routing In Number Control Profile

 When enabled, SBC checks for redirection capabilities for the number used for routing. The options are:

  • Enable
  • Disable (default)
Check Sip Indirect Dip And Username Translation Source Number

 When enabled, SBC checks whether the received request is a SIP Indirect DIP and whether it contains the Translation Source Number. The options are:

  • Enable
  • Disable (default)
Create Called Directory Number in Egress Signal On Redirection

When enabled, the original called party is sent by the GSX as the Called Directory Number. The options are:

  • Enable
  • Disable (default)
Skip Redirection On RACIndication Set

When enabled, if the Representative Area Code indicator is set to On in the JTI parameter, the GSX does not perform redirection. The options are:

  • Enable
  • Disable (default)