The

Spacevars
0product
 (SBC) The Sonus SBC 1000/2000 system allows you to remotely shut down and power up the Application Solution Module (ASM) via the WebUI. Below are some of the common reasons why System Administrators would want to shut down the ASM:

  • If you plan on physically re-locating the Sonus SBC 1000/2000 system, it is recommended to shut down the ASM first
  • If the ASM is running and wish to temporarily disable it
  • Useful when troubleshooting
Note
titleSonus SBC 1000/2000 Model Differences
  • Sonus SBC 1000
    • Does not shutdown or restart when Sonus SBC 1000/2000 is rebooted.
    • The Power off is achieved via the hardware and does not need Sonus SBC 1000/2000 communication service to be operational.
  • Sonus SBC 2000
    • If the Sonus SBC 1000/2000 is rebooted, the ASM is automatically restarted. This makes it more important to shutdown the ASM before powering off (or relocating) the Sonus SBC 1000/2000 unit.
    • The power off is initiated via the Sonus SBC 1000/2000 communications service and thus needs the service to be operational for the command to work.

...

  1. In the WebUI, click the Tasks tab.
  2. In the left navigation pane, under the Application Solution Module, click Shut Down/Reset/Reboot.

    Panel
    borderStylenone

    Caption
    0Figure
    1Shut Down ASM

    Image Modified 

  3. Select Shut Down
  4. Click Apply

...

  1. In the WebUI, click the Tasks tab.
  2. In the left navigation pane, under the Application Solution Module, click Shut Down/Reset/Reboot.

    Panel
    borderStylenone

    Caption
    0Figure
    1Power On ASM

    Image Modified

  3. Select Power On
  4. Click Apply

This operation typically takes a few minutes to complete.