Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a0c86820e56901685f374974002d, userName='null'}
JIRAIDAUTHSBX-120567
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a0c86a195e2c016a58a5ab600022, userName='null'}
REV4UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cdec0ad4, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26ceaa0c34, userName='null'}

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.4.0.70

Description

This alarm indicates that SIP Register License threshold is cleared. The threshold limit is 90% of the maximum license count.

Note: The Alarm is cleared when the threshold falls back to 80% of the maximum license count but not if it happens within 5 seconds. For example, if the registration count reaches 90% of the maximum license count and the very next second the count reaches to 80% of the maximum license count (due to a registration expiration), then the alarm is not cleared immediately. After 5 seconds, if the registration count is lesser than 80% of max license count, then the alarm is cleared. This control is implemented to control the flooding of alarms in the system.

Repetition

None

Event Codes

  •  sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription

Instance Fields

  • sonusSipRegLicenseClearThreshold
  • sonusSipRegLicenseLimit

Action

None. SIP license threshold is cleared.

Impact

The alarm indicates that SIP Register License Threshold is cleared. REGISTER messages are no longer rejected.

Clearing

Automatic; sonusSipRegThresholdReachedNotification