Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.10.1.1.4.0.70 |
Description | This alarm indicates that SIP Register License threshold is cleared. The threshold limit is 90% of the maximum license count. Note: The Alarm is cleared when the threshold falls back to 80% of the maximum license count but not if it happens within 5 seconds. For example, if the registration count reaches 90% of the maximum license count and the very next second the count reaches to 80% of the maximum license count (due to a registration expiration), then the alarm is not cleared immediately. After 5 seconds, if the registration count is lesser than 80% of max license count, then the alarm is cleared. This control is implemented to control the flooding of alarms in the system. |
Repetition | None |
Event Codes |
|
Instance Fields |
|
Action | None. SIP license threshold is cleared. |
Impact | The alarm indicates that SIP Register License Threshold is cleared. REGISTER messages are no longer rejected. |
Clearing | Automatic; sonusSipRegThresholdReachedNotification |