The DC power supply is a Customer Replaceable Unit (CRU). The product codes are:
Caption | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||
* End of Product Sale as of April 20, 2015 |
In a dual redundant Power Supply configuration, the Power Supplies are hot-swappable meaning that a Power Supply may be replaced without powering down the
Spacevars | ||
---|---|---|
|
Note | ||||
---|---|---|---|---|
| ||||
Before replacing a Power Supply in a redundant Power Supply configuration, verify the status of the redundant Power Supply. The “POK” LED status must be “solid green”. Removing the Power Supply when the redundant Power Supply does not show a solid green status, may cause the system to power down. Contact
|
Caption | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
|
Note |
---|
The chassis is shipped with one Power Supply, unless a second Power Supply is added to the order. |
Include Page | ||||
---|---|---|---|---|
|
Perform the following procedure to replace a Power Supply:
Remove clear plastic protective cover on terminal strip.
Caption | ||||
---|---|---|---|---|
| ||||
Disconnect RTN and -48V connections by loosening two terminal strip screws using the #2 Philips screwdriver.
Caption | ||||
---|---|---|---|---|
| ||||
Spacevars | ||
---|---|---|
|
Tooltip | ||
---|---|---|
| ||
All
Spacevars | ||
---|---|---|
|
The storage environment for these CRUs is:
Include Page | ||||
---|---|---|---|---|
|
Pagebreak |
---|