The console settings for the system are:

  • Baud Rate: 9600
  • Data Bits: 8
  • Parity: None
  • Stop Bits: 1
  • Flow Control: None

The pinout of the Console cable RJ45-to-DB9 is given below.

Caption
0Figure
1Console Cable
3Console Cable

Image Modified


Caption
0Table
1Console cable pinout table
3Console cable pinout table


SignalDB9 PinRJ45 PinSignal
-1 - NCNC-
RXD23TXD
TXD36RXD
-4 - NCNC-
GND54GND
-6 - NCNC-
-7 - NCNC-
-8 - NCNC-
-9 - NC--

Legend

NC: Not Connected

TXD: Transmit Data

RXD: Receive Data