Type: MAJOR

Object ID

...

Description

...

1.3.6.1.4.1.2879.2.8.1.2.1.5.0.50

Description

This alarm indicates that the system is running out of memory and will soon reboot.

Repetition

None

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusNodeOverloadType
sonusNodeOverloadLevel
sonusNodeOverloadThresholdCurrent
sonusNodeOverloadThresholdConfigured

Instance Fields

...

sonusNodeOverloadType
sonusNodeOverloadLevel
sonusNodeOverloadThresholdCurrent
sonusNodeOverloadThresholdConfigured

Action

...

Check call/registration load and possible resource leakage.

Impact

...

Calls may get rejected.

Clearing

Automatic

...

; sonusSystemNodeResourceClearCongestionWarningNotification


Info
titleNote

For the SBC SWe, this alarm is also generated when there is a CPU congestion. Calls may get rejected during congestion to maintain system stability.


Info
titleNote

If the node overload type mentioned in the alarm is "mem" then, the SBC application restarts only when the memory threshold of 90% is breached. If the node overload type is "XRM" in the alarm, then the SBC does not restart.