Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 

Use this window to define the

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to Configuration

Back to Configuration - System Provisioning

Back to Category - SIP Carrier Peering

Back to SIP Carrier Peering - Sip Trunk Group

Back to SIP Carrier Peering: Sip Trunk Group - Signaling

...

prescribed behavior associated with various 3GPP P-Headers.

To View and Edit P-Header Extensions

On the SBC main screen, go

...

to Configuration

...

 > System Provisioning

...

 > Category: SIP Carrier

...

Peering >

...

 Signaling > P-Header Extensions. The P-Header Extensions window is displayed.

...

 

Excerpt

Use the drop-down

...

boxes to select the desired Address Context, Zone and

...

SIP Trunk Group.

...

The Edit P-Header Extensions window is displayed.

Caption
0Figure
1SIP Carrier Peering - Signaling - P-Header Extensions

Image Added

...

 

The following

...

parameters can be configured:

Caption
0Table
1P-Header Extension parameters

Parameter

Description

Use Ingress Orig Ca

Enable to honor P-Orig-CA header received on the ingress side.

...

  • Disabled (default)

...

  • Enabled

Add Egress Orig Ca

Enable to send P-Orig-CA header on the egress side.

...

  • Disabled (default)

...

  • Enabled

Insertp Visited Network ID

...

When the SBC is acting as a P-CSCF, use this parameter to

...

specify the P-Visited-Network-ID header value

...

(for example, visitedNetwork or “\”Visited Network\””) for the SBC to insert in a REGISTER request it receives from a UE before that request is forwarded towards the IMS core network. The value

...

can be up to 255 characters.

Make the required changes and

...

click Save.

...