Page History
...
- Access a compatible web browser.
- In the browser, enter the IP address of the
in the URL address bar. The Welcome to Ribbon screen is displayed.Spacevars 0 product - Review the Pre-Login message.
- Enter the administrator User Name and Password configured during initial setup.
- If the Acknowledge Pre-Login Message checkbox is displayed, click on it to acknowledge you have reviewed the pre-login information above. After initial login, you can enable and disable this checkbox via the Global Security Options. By default, this checkbox is configured as disabled.
Click Login. The main screen provides all WebUI functions, including tabbed options, menu tree, device name, and the last login date and time of the system.
Select Settings > System > Node-Level Settings.
Note title Caution When you enter the Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the
cannot connect to the Ribbon Application Management Platform.Spacevars 0 product3 Use the following table to configure the Ribbon Application Management Platform (RAMP) panel.
Ribbon Application Management Platform ParametersParameter Description Connect to RAMP Configure this field to enable or disable the Ribbon Application Management Platform.
- No (default) - The Ribbon Application Management Platform is disabled.
- Yes - The Ribbon Application Management Platform is enabled.
- Yes with Redundancy.
Management Address Configure this field with the IP address or FQDN of the Ribbon Application Management Platform.
Note: This field applies only when the RAMP field is set to Yes.
Management ID Caution: When you enter the Ribbon Application Management Platform Management ID, you must insert a colon every two characters (00:00:00). Otherwise, the
cannot connect to the Ribbon Application Management Platform.Spacevars 0 product3 Configure this field with the Management ID for the Ribbon Application Management Platform.
Note: This field applies only to the
. The SBC 1000/2000 automatically sends the Management ID to the Ribbon Application Management Platform.Spacevars 0 product3 Note: This field applies only when the Connect to RAMP field is set to Yes.
RAMP Connection The status of the SBC’s connection to the Ribbon Application Management Platform. This status may be one of the following:
- Down
- Up
Note: This field applies only when the Connect to RAMP field is set to Yes.
RAMP Tunnel Status The status of the HTTPS tunnel from the RAMP to the SBC. This status may be one of the following:
- Not Connected
- Up
Note: This field applies only when the RAMP field is set to Yes.
RAMP Online Licensing The status of the RAMP Licensing on the SBC. This status may be one of the following:
- None
- NWDL
- SBCaaS (Ribbon Connect)
Note: This field applies only to the
.Spacevars 0 product3 Note: This field applies only when the RAMP field is set to Yes.
HA Pair Name Enter the name of the Active and Standby instance to be paired. RAMP uses this string to identify both active and standby instances. So, enter the same string for both Active and Standby instances. The string must contain only alphanumeric characters.
The HA pair name allows RAMP to identify the Active and Standby SWe Edge HA instances as a single network entity.
- Click Apply.
...