Page History
Add_workflow_for_techpubs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.8.1.2.1.19.0.4 | |||||||||||||
Description | This alarm indicates that the License Manager has rejected the registration request. | |||||||||||||
Repetition | Repeats for each occurrence. | |||||||||||||
Event Codes | EVENT_LICENSE_MANAGER_SERVER_REGISTRATION_FAILED | |||||||||||||
Instance Fields |
| |||||||||||||
Action | Check the logs on the License Manager and correct the issues listed. | |||||||||||||
Impact | The SBC will not be able to register with the EMS/RAMP.
| |||||||||||||
Clearing | automatic; sonusCpLicenseManagerRegistrationSucceeded |
Overview
Content Tools