Add_workflow_for_techpubs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.8.1.2.1.5.0.50 |
Description | This alarm indicates that the system is running out of memory and will soon reboot. |
Repetition | None |
Event Codes | sonusAlarmNodeID |
Instance Fields | sonusNodeOverloadType |
Action | Check call/registration load and possible resource leakage |
Impact | Calls may get rejected |
Clearing | Automatic, sonusSystemNodeResourceClearCongestionWarningNotification |
Info | ||
---|---|---|
| ||
For the SBC SWe, this alarm is also generated when there is a CPU congestion. Calls may get rejected during congestion to maintain system stability. |
Info | ||
---|---|---|
| ||
If the node overload type mentioned in the alarm is "mem" then, the SBC application restarts only when the memory threshold of 90% is breached. If the node overload type is "XRM" in the alarm, then the SBC does not restart. |