Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

add_docset_workflowworkflow_for_techpubs
SYM-20602
APPRJIDSYM-20603
AUTH1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26ced70caa8a00a0c85b2726c2015b58aa779d0003, userName='null'}
JIRAIDAUTHSYM-22879
REV5DEV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c7f0006a8a00a0c85b2726c2015b58aa779d0003, userName='null'}
LDEV1REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26ced70caa8a00a0c85b2726c2015b58aa779d0003, userName='null'}
SVT1REV3UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cba306258a00a02355cd1c2f0155cd26c87d0111, userName='null'}
LSVT1REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26ced70caa8a00a02355cd1c2f0155cd26cc5207f0, userName='null'}AUTHJID

Available_since
TypeModified For
Release6.1.4

 

 

This section details all 

Spacevars
0product
alarms and events. The 
Spacevars
0product
displays these alarms in the Viewing Alarms and Events and are configured in the Configuring Alarms and Events page.

Panelnote

Hardware related Alarms and Events are not applicable for

Spacevars
0product3
. 

Table of Contents

Alarm and Event Subsystems

...

Div
classpdf6pttext

ID

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

1

1

alarm

AD caching failed

communication

System;Service;IPAddress

minor

(tick)

  • Failed to cache attributes from AD in memory.
  • Suggested action - try again later.
  • This alarm will be cleared by event AD caching successful.

1

2

event

Online AD query failed

communication

System;Service

 

 

  • Failed to execute AD query.
  • Suggested action - confirm that AD is network reachable, check the AD configuration as well as AD access credentials.

1

4

event

User logged in

security

Username;IPAddress

 

 

  • New user [username] logged in from [ip address] at [time].

1

5

alarm

User login failed

security

Username;IPAddress

major

(tick)

  • User [username] login failed from [ip address] at [time].
  • This alarm will be cleared by event User logged in.

1

6

alarm

AD Unreachable

communication

System:Service;IPAddress; DCType

major

(tick)

  • Either AD is network unreachable, or the AD credentials are invalid.
  • DCType will be either Authentication or Call Route
  • This alarm will be cleared by 'AD Reachable' event.

1

7

event

AD Reachable

communication

System:Service;IPAddress; DCType

 

 

  • Active directory is now reachable.
  • DCType will be either Authentication or Call Route

1

8

event

AD caching successful

communication

System:Service;IPAddress

 

 

  • AD caching was successful.

1

9

alarm

AD backup failed

equipment

System:Service;IPAddress

minor

(tick)

  • Failed to backup cached values from AD to storage device.
  • Either the storage device is not present, or it is full.
  • Contact Sonus TAC for further assistance.

1

10

event

AD successfully backed up

equipment

System:Service;IPAddress

 

 

  • Successful backup of cached values from AD to storage device.

1

11

alarm

AD cache truncated

equipment

System:Service

minor

 

  • AD Cache is truncated, AD cache results have exceeded the maximum cache size.
  • Consider caching only the required attributes.
  • If the query is not found in cache, Online query will be performed, while affecting performance.

1

12

alarm

RADIUS Server Unreachable

communication

System:Service;IPAddress

major

(tick)

  • Either the RADIUS server is network unreachable, or the configuration is incorrect.
  • Suggested action - check shared secret, listening port, RADIUS server IP.
  • This alarm will be cleared by 'RADIUS Reachable' event.

1

13

event

RADIUS Reachable

communication

System:Service;IPAddress

 

 

  • RADIUS server is online.

1

14

alarm

CDR logging failed

communication

System:Service;IPAddress

major

 

  • Sonus SBC 1000/2000 failed to send CDR to RADIUS based accounting server.
  • Either the RADIUS server is network unreachable, or the configuration is incorrect.
  • Suggested action - check shared secret, listening port, RADIUS server IP.

1

15

alarm

CDR backup failed

communication

System:Service;IPAddress

major

 

  • Sonus SBC 1000/2000 failed to backup CDR in local file.
  • Either running with low disk space or CDR backup maximum limit is crossed.
  • Suggested action - Free up the disk space or save the CDR Queued file for future reference.

1

17

event

User password changed successfully

Security

Username

 

 

  • Logged any time password is changed by specified user or an administrator.
  • Event Text: User 'username' password changed successfully by 'username' from 'IP address'.

    Info

    If not preceded by a password expired event, this was a voluntary password change.

1

18

alarm

User password change failed

Security

Username

warning

(tick)

  • Logged any time an attempted password change failed by specified user or an administrator.
  • Event Text: User 'username' password change attempted by 'username' from 'IP address" failed.
  • Cleared by event 1.17 - User password changed successfully.

    Info

    If not preceded by a password expired event, this was a voluntary password change.

1

19

event

User account disabled

Security

Username

 

 

  • Event Text: User 'username' account has been disabled by 'username' from 'IP address'.

1

20

event

User account activated

Security

Username

 

 

  • Event Text: User 'username' account has been activated by 'username' from 'IP address'.

1

21

event

Global Security Options Changed

Security

Username;IPAddress

 

 

  • Event Text: Global security options changed by 'username' from 'IP address'.

1

22

alarm

User login blocked

Security

Username

major

(tick)

  • Event Text: User 'username' blocked from login due to excessive incorrect login attempts.
  • Cleared by event 1.23 - User login unblocked.

1

23

event

User login unblocked

Security

Username

 

 

  • Event Text: User 'username' unblocked.
124eventUser password expiredSecurityUsername;IPAddress  
  • Password has expired.
125alarmAD: Maximum Threads ExceededProcessingSystem;Servicemajor 
  • AD has reached maximum threads. Please inform your service representative.
126alarmAD caching timed outcommunicationSystem;Service;IPAddressminor Timed out caching attributes due to lack of response from AD. Suggested action - try again later. The SBC will attempt to load the last successful cache from backup.

Resource Manager

ID

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

2

1

alarm

Invalid Card ID EEPROM Data

equipment

System;Card

critical

 

  • A Card was detected with invalid Card ID EEPROM contents (failed CRC-CCITT check).
  • Suggested action - provide the entire alarm message including the numbers at the end to Sonus TAC for further assistance.

2

2

alarm

Card Health Check Failed

equipment

System;Card

critical

 

  • During Line Card activation, a Card Fault was detected after power was applied to the card.
  • The Card will remain out-of-service.
  • Suggested action - reboot system.
  • If issue persists, contact Sonus TAC with the alarm information.

2

3

alarm

Card not Supported

equipment

System;Card

major

 

  • A Card was detected which can be identified, but the Sonus SBC 1000/2000 system software is unable to support.
  • The Card will remain out-of-service.
  • Suggested action - reboot system.
  • If issue persists, contact Sonus TAC with the alarm information.

2

4

alarm

Power Supply input failure

equipment

System;PSU

major

(tick)

  • A Power supply module has indicated a failure of input power.
  • The Sonus SBC 1000/2000 System has lost Power Supply redundancy.
  • Suggested action - Verify that the power cable is connected and that the PS is functioning properly.

2

5

event

Power Supply input restored

equipment

System;PSU

 

 

  • A Power Supply module has indicated that input power has been restored.
  • This event clears the "Power Supply Input Failure" Alarm.

2

6

alarm

Power Supply output failure

equipment

System;PSU

major

 

  • A Power Supply module has indicated a failure of output power.
  • The Sonus SBC 1000/2000 System has lost Power Supply redundancy.
  • Suggested action - Verify that the PS is functioning properly.

2

7

alarm

Single Fan failure

equipment

System;Fan

major

 

  • Check the System tab to find the Fan ID of the failed fan.
  • Contact Sonus TAC with this information.

2

8

alarm

Multiple Fan Failures

equipment

System;Fans

critical

 

  • Check the System tab to find the Fan ID's of the failed fans.
  • Contact Sonus TAC with this information.

2

9

alarm

System Temperature Warm

equipment

System

minor

(tick)

  • The temperature sensors have indicated that the system is running warm (65°C threshold).

2

10

event

System Temperature Warm Cleared

equipment

System

 

 

  • The temperature sensors have indicated that the system is NO LONGER running warm (55°C threshold).
  • This event clears the "System Temperature Warm" Alarm.

2

11

alarm

System Temperature Hot

equipment

System

critical

(tick)

  • The temperature sensors have indicated that system is running hot.

2

12

event

System Temperature Hot Cleared

equipment

System

 

 

  • The temperature sensors have indicated that the system is NO LONGER running hot (65°C threshold).
  • This event clears the "System Temperature Hot" Alarm.

Licensing

ID

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

3

1

alarm

Licenses expired.

general

System;Service

critical

(tick)

  • License of the node has expired, all the licensed features would fail to work.
  • Contact Sonus Sales.

3

2

alarm

License expires in 2 weeks.

general

System;Service

major

(tick)

  • License of the node will expire in 2 weeks.

3

3

event

New License applied.

general

System;Service

 

 

  • New License is applied on the node.

3

4

alarm

Failed to Apply License.

general

System;Service

critical

 

  • Either an invalid key is used, or the license key applies to a different node, or the license key expiry is past the present date.
  • Contact Sonus Sales to obtain a new license.

3

5

alarm

Failed to acquire license.

general

System;Service

critical

 

  • The alarm is generated when the required license is not available.
  • Check the number of licensed SIP or TDM channels, the number of SIP registrations, SBA, Transcoding or AD.
  • Suggested action - obtain license for missing functionality.
36alarmLicensed DS1 ports exceed installed ports.generalSystem;Servicecritical 
  • This alarm is generated when the license key applied has more TDM ports licensed than are installed in the system. As a fix, obtain license with correct number of TDM ports.
37alarmLicensed BRI ports exceeds installed ports.generalSystem;Serviceminor 
  • The alarm is generated when the license key applied has more BRI ports licensed than are installed in the system. The number of BRI ports installed will get activated. As a fix, obtain a license with the correct number of BRI ports.
38alarmLicensed FXS ports exceeds installed ports.generalSystem;Serviceminor 
  • The alarm is generated when the license key applied has more FXS ports licensed than are installed in the system. The number of FXS ports installed will get activated. As a fix, obtain a license with the correct number of FXS ports.
39alarmLicensed FXO ports exceeds installed ports.generalSystem;Serviceminor 
  • The alarm is generated when the license key applied has more FXO ports licensed than are installed in the system. the number of FXO ports installed will get activated. As a fix, obtain a license with the correct number of FXO ports.

Microsoft Survivable Branch Appliance Support

ID

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

5

1

alarm

ASM Unreachable

communication

SBA Instance

critical

(tick)

  • ASM system can not be reached, system is down.
  • Check whether the ASM is rebooting.

5

2

event

Clear ASM Unreachable

communication

SBA Instance

 

 

  • Clears alarm 'ASM Unreachable'.

5

3

alarm

ASM Failure Recovered

equipment

SBA Instance

minor

 

  • ASM system was previously unreachable, but has come up.
  • This alarm doesn't autoclear so the user can investigate the cause, but the system should be working correctly now.

5

4

alarm

ASM Services Not Running

processing

SBA Instance

critical

(tick)

  • ASM services are not running, calls through the ASM cannot be placed.

5

5

event

Clear ASM Services Not Running

processing

SBA Instance

 

 

  • Clears alarm 'ASM Services Not Running'.

5

6

alarm

ASM Services Restarted

processing

SBA Instance

minor

 

  • ASM Services was previously stopped, but has started. This alarm doesn't autoclear so the user can investigate the cause, but ASM Services should be working correctly now.

5

7

alarm

ASM Service Restart Failed

processing

SBA Instance

critical

 

  • The system attempted to restart a failed service on the ASM, service did not start successfully.
  • User interaction is required.

5

8

event

ASM System Started

processing

SBA Instance

 

 

  • This event is set when the SBA communication system is first established, and usually indicates that the Application Solution Module (ASM) has finished booting.
  • It should come up at system startup, it may come again if the ASM hardware is rebooted.

5

9

event

ASM System Shutting down

processing

SBA Instance

 

 

  • A planned or deliberate shut down is taking place on the Application Solution Module (ASM).

5

10

alarm

Ethernet Link Down

equipment

SBA Instance;Port

major

(tick)

  • Ethernet port specified has lost link.
  • Source Instance: Eth0/Eth1 via SBA Monitor.

5

11

event

Ethernet Link Up

equipment

SBA Instance

 

 

  • Ethernet port specific has recovered link.

5

12

alarm

ASM-SBC IP Subnet Mismatch

equipment

SBA Instance

critical

(tick)

  • The ASM and Sonus SBC IP interfaces are in different subnets and cannot communicate.

5

13

event

ASM-SBC IP Subnet Match

equipment

SBA Instance

 

 

  • The ASM and Sonus SBC IP interfaces are in the same subnet and can now communicate.
514alarmASM-QoE SQL database is unreachablecommunicationSBA Instancemajor(tick)
  • The QoE database is unreachable from ASM, make sure the Lync Server 2013 is deployed and Monitoring database is running.
515eventClear ASM-QoE SQL database is unreachableequipmentSBA Instance  
  • The QoE database is now reachable from ASM.
516alarmASM-failed to store QoE informationequipmentSBA Instancecritical 
  • Failed to store the QoE information from ASM.
517alarmASM-SBC CAC Update FailedequipmentSBA Instancemajor(tick)
  • The ASM hasn't been able to apply the CAC update.
518eventASM-SBC CAC Update AppliedequipmentSBA Instance  
  • ASM-SBC CAC Update applied.
519alarmThis copy of ASM Operating System is not genuineequipmentSBA Instancecritical 
  • ASM Windows Server is not able to activate as genuine Microsoft product.
520alarmASM drive NFS mount failureequipmentSBA Instancemajor(tick)
  • NFS mounting of ASM drive failed, make sure ASM module is up and NFS service is running on the ASM module.
521eventClear ASM drive NFS mount failureequipmentSBA instance  
  • ASM hard drive is NFS mounted and available.
522eventASM Operating System Successfully ActivatedequipmentSBA instance  
  • ASM Windows Server is activated as genuine Microsoft product.

5

23

Alarmalarm

ASM IP Address conflict

SBA

SBA Instance

Criticalcritical

(tick)

  • The configured ASM IP was not applied due to conflict with other device(s) on the network.

5

24

Eventevent

Clear ASM IP address conflict

SBA

SBA Instance

 

 

  • ASM IP address conflict cleared.
Call Routing
IDActSetTble
525

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

alarmASM Ethernet Port DownequipmentSBA instancecritical(tick)
  • ASM Etherent Port has been detected down.
526eventClear ASM Ethernet Port DownequipmentSBA instance

7

1

event

Configuration change occurred on Action Set

general

  
  • There is an action set table number/name that should be printed with this event.
  • ASM Ethernet Port has been detected down is cleared.
527alarmActive CCE Maintenance ModeequipmentSBA instancecritical(tick)
  • Cloud Connector Edition entered in Maintenance mode.
528eventClear Active CCE Maintenance ModeequipmentSBA instance  
  • Cloud Connector Edition exited maintenance mode.
529alarmCCE Windows Product Key is missingequipmentSBA instancemajor(tick)
  • Cloud Connector Edition Windows Product Key is missing.
530eventClear CCE Windows Product Key is missing or failed to activate
equipmentSBC instance  
  • Cloud Connector Edition Windows Product Key has been found.
531alarmCCE Windows Product Failed to ActivateequipmentSBA instancemajor(tick)
  • Cloud Connector Edition Windows Product Failed to Activate

Call Routing

ID

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

7

1

event

Configuration change occurred on Action Set

general

ActSetTble

 

 

  • There is an action set table number/name that should be printed with this event.

7

2

event

Configuration change occurred on Normalization Table

general

NormTble

 

 

  • There is a normalization table number/name that should be printed with this event.

7

3

event

Configuration change occurred on Route Table

general

RtTble

 

 

  • There is a route table number/name that should be printed with this event.

7

4

event

Configuration change occurred on Transformation Tables

general

TransTble

7

2

event

Configuration change occurred on Normalization Table

general

NormTble

 

 

  • There is a normalization table number/name that should be printed with this event.

7

3

event

Configuration change occurred on Route Table

general

RtTble

 

 

  • There is a route table number/name that should be printed with this event.

7

4

event

Configuration change occurred on Transformation Tables

general

TransTble

 

 

  • There is a transformation table number/name that should be printed with this event.

7

5

alarm

Route temporarily disabled

communication

RtTble

warning

(tick)

  • This alarm is set if a link is down or some other event has occured to take a route entry out of service.

7

6

event

Route enabled

communication

RtTble

 

 

  • Route came up.

7

7

alarm

A Call exceeded the limit for number of destinations

communication

CallDest

warning

 

  • A call with destination of X tried to be forked more than the limit allows (currently 8).

7

8

alarm

Call forking used with no forking license

communication

CallDest

warning

 

  • A call with a destination of X was forked with no forking license available.

7

9

alarm

Invocation of InvokeActionSet exceeded the maximum nesting limit

communication

CallDest

warning

 

  • A call with with destination of X tried to execute InvokeActionSet more the the limit allows (currently 10).

7

10

event

Configuration change occurred on Callback Tables

general

CallbackTble

 

 

  • There is a PSAP Callback transformation table number/name that should be printed with this event.

7

Common Call Control

5

ID

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

alarm

Route temporarily disabled

communication

RtTble

warning

(tick)

  • This alarm is set if a link is down or some other event has occured to take a route entry out of service.

7

6

event

Route enabled

communication

RtTble

8

1

event

Channel is in service

communication

Card;Port;Channel

 

 

  • Channel is up and is in service.
  • This clears the 'Channel out of service' alarm.
  • Route came up.

7

7

alarm

A Call exceeded the limit for number of destinations

communication

CallDest

warning

 

  • A call with destination of X tried to be forked more than the limit allows (currently 8).

7

8

alarm

Call forking used with no forking license

communication

CallDest

warning

 

  • A call with a destination of X was forked with no forking license available.

7

9

alarm

Invocation of InvokeActionSet exceeded the maximum nesting limit

communication

CallDest

warning

 

  • A call with with destination of X tried to execute InvokeActionSet more the the limit allows (currently 10).

7

10

event

Configuration change occurred on Callback Tables

general

CallbackTble

 

 

  • There is a PSAP Callback table number/name that should be printed with this event.

Common Call Control

Call Attempt failed due to Media Mode mismatchThe call failed due to Media Mode mismatch across SG and Call Route configuration8All calls have been drained on this Signaling Group

ID

Sub-ID

Type

Default Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

8

1

event

Channel is in service

8

2

alarm

Channel is out of service

communication

Card;Port;Channel

minor

(tick)

  • Channel Out Of Service Alarm.
  • This alarm is automatically cleared when Channel is in service.

8

3

alarm

Emergency Call Attempted

communication

Number;Extension;IPAddress

minor

(tick)

  • Emergency Call is Attempted from Calling Number, Calling Extension, Caller IP address.

8

4

event

Emergency Call Attempted

communication

Number;Extension;IPAddress

 

 

  • Emergency Call Alarm will be cleared after expiry time in emergency status table.
85alarm

QoE report not sent due to RTCP Media List

communicationSGminor 
  • Generated when the Media List does not have RTCP-XR configuration enabled.
86eventCall Transfer failed due to call not being in RTP modecommunicationCard;Port;Channel  
  • The call is not in RTP mode hence the call transfer could not be honored.
87event

communication

Card;Port;Channel

 

 

  • Channel is up and is in service.
  • This clears the 'Channel out of service' alarm.

8

2

alarm

Channel is out of service

communication

SGWarning  

SIP

Card;Port;Channel

minor

(tick)

  • Channel Out Of Service Alarm.
  • This alarm is automatically cleared when Channel is in service.

8

3

alarm

Emergency Call Attempted

communication

Number;Extension;IPAddress

minor

(tick)

  • Emergency Call is Attempted from Calling Number, Calling Extension, Caller IP address.

8

4

event

Emergency Call Attempted

communication

Number;Extension;IPAddress

 

 

  • Emergency Call Alarm will be cleared after expiry time in emergency status table.
85alarm

QoE report not sent due to RTCP Media List

communicationSGminor 
  • Generated when the Media List does not have RTCP-XR configuration enabled.
86eventCall Transfer failed due to call not being in RTP modecommunicationCard;Port;Channel  
  • The call is not in RTP mode hence the call transfer could not be honored.
87eventCall Attempt failed due to Media Mode mismatchcommunicationCard;Port;Channel  
  • The call failed due to Media Mode mismatch across SG and Call Route configuration.
88alarmAll calls have been drained on this Signaling GroupcommunicationSGWarning  

SIP

Successfully bound to network interface bound to network interface. DHCP lease renewed.20 Register Server not responding;Protocol;IPAddress;Port Register server has failed to respond. This alarm will be cleared by the event "SIP Regular server became responsive"21 Register became  unresponsive;Protocol;IPAddress;Port Register server came up24QoE Notify Message was not successfulQoE Notify Message Response was successful SIP application session processing is overloaded27SIP overload clearedSystem;ServiceSIP application session processing resumes to normal operation, overload cleared28 maximum sessions per SG reachedThe maximum number of SIP sessions (calls/register/subscribe) has been reached on the signaling group. Increase the number of SIP Channels for the signaling group29Maximum Number of SIP Sessions Alarm ClearedSG sessions per signaling group is under the maximum limit32Handshake response was started with valid certificate on local and remote gateway. This event clears the 'SIP-TLS Handshake Negotiation Start Failure' alarm.

A Presence Publish Request has been sent to the configured Skype/Lync Presence Front End and either:

  • no response has been received, or
  • the response failed.

    Only one alarm is raised at any time. The alarm is cleared when the SIP presence entity receives a successful response to a Publish message.

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    9

    1

    alarm

    SIP Server not responding

    communication

    SIPCluster;ServID;Protocol;IPAddress;Port

    major

    (tick)

    • SIP server has failed to respond and has been taken out of service.
    • This alarm will be cleared by the event 'SIP server became responsive'.

    9

    2

    alarm

    Signaling Group taken out of service

    communication

    SG

    critical

    (tick)

    • All servers in SG have failed

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    9

    1

    alarm

    SIP Server not responding

    communication

    SIPCluster;ServID;Protocol;IPAddress;Port

    major

    (tick)

    • SIP server has failed to respond and has been taken out of service.
    • This alarm will be cleared by the event 'SIP server became responsive'.

    9

    2

    alarm

    Signaling Group taken out of service

    communication

    SG

    critical

    (tick)

    • All servers in SG have failed.
    • This alarm will be cleared by 'SIP Signaling group enabled' event.

    9

    3

    event

    Signaling Group disabled

    communication

    SG

     

     

    • Configuration action has changed this Signaling Group from Enabled to Disabled.

    9

    4

    alarm

    SIP-TLS Server Handshake Failure

    security

    TLSProfile;IPAddress

    minor

     

    • TLS server handshake failed with alert code. Action: Refer to Error Alerts in RFC 5246 for the problem.

    9

    5

    alarm

    SIP-TLS Handshake Inactivity Timeout Failure

    security

    TLSProfile;IPAddress

    minor

     

     

    9

    6

    alarm

    Configured port number mismatch

    processing

    SG;IPAddress;Port

    minor

     

    • Discrepancy of an FQDN/Port configured in the SipServer object that is different than the DNS SRV lookup.
    • A DNS SRV record can return the port number for the selected protocol.
    • The DNS SRV port value will take priority over the configured port.

    9

    7

    event

    SIP Server became responsive

    communication

    SIPCluster;ServID;Protocol;IPAddress;Port

     

     

    • SIP server came up.

    9

    8

    alarm

    SIP cluster went down

    communication

    SIPCluster

    major

    (tick)

    • SIP cluster went down.
    • This is due to all the servers in the clusters are not responsive.
    • This alarm will be cleared by the event 'Sip cluster 'SIP Signaling group enabled' .

    9

    9

    • event

    SIP Cluster enabled

    communication

    SIPCluster

     

     

    • SIP cluster enabled.

    9

    103

    event

    SIP Signaling group enabledGroup disabled

    communication

    SG

     

     

    • SIP Signaling group enabledConfiguration action has changed this Signaling Group from Enabled to Disabled.

    9

    114

    alarm

    SIP Signaling group: DNS failure

    communication

    SG

    major

    (tick)

    • Failed to resolve the FQDN entries in the SIP Signaling Group. Suggested action - confirm the FQDNs, and confirm DNS access.

    9

    12

    event

    SIP Signaling Group; FQDN resolved

    communication

    SG

     

     

    • Successfully resolved the FQDN of the SIP Signaling group.

    9

    13

    alarm

    SIP Server; DNS failure.

    communication

    SIPCluster;ServID

    major

    (tick)

    • Failed to resolve the SIP server FQDN entries in the SIP Server table.
    • Suggested action - check the FQDN syntax.

    9

    14

    event

    SIP Server; FQDN resolved

    communication

    SIPCluster;ServID

     

     

    • SIP Server config FQDN resolved.

    9

    15

    alarm

    SIP call session DNS failure

    communication

    SG

    major

     

    • Failed to resolve an FQDN with DNS server during a SIP call session.

    9

    16

    alarm

    Acquiring license for Register failed

    communication

    SG

    major

     

    • Failed to acquire license from License Manager.
    917alarmSession leak or some other resource leakcommunicationSGmajor 
    • SIP performs self-check for leaks. Please enable logging for sip and issue "show resources" command.
    918alarmFailed to bind to network interfacecommunicationSGminor

    (tick)

     

    • Failed to bind to network interface due to dynamic IP address not available.

    -TLS Server Handshake Failure

    security

    TLSProfile;IPAddress

    minor

     

    • TLS server handshake failed with alert code. Action: Refer to Error Alerts in RFC 5246 for the problem.

    9

    5

    alarm

    SIP-TLS Handshake Inactivity Timeout Failure

    security

    TLSProfile;IPAddress

    minor

     

     

    9

    6

    alarm

    Configured port number mismatch

    processing

    SG;IPAddress;Port

    minor

     

    • Discrepancy of an FQDN/Port configured in the SipServer object that is different than the DNS SRV lookup.
    • A DNS SRV record can return the port number for the selected protocol.
    • The DNS SRV port value will take priority over the configured port.

    9

    7

    event

    SIP Server became responsive

    communication

    SIPCluster;ServID;Protocol;IPAddress;Port

     

     

    • SIP server came up.

    9

    8

    alarm

    SIP cluster went down

    communication

    SIPCluster

    major

    (tick)

    • SIP cluster went down.
    • This is due to all the servers in the clusters are not responsive.
    • This alarm will be cleared by the event 'Sip cluster enabled'.

    9

    9

    event

    SIP Cluster enabled

    communication

    SIPCluster

     

     

    • SIP cluster enabled.

    9

    10

    event

    SIP Signaling group enabled

    communication

    SG

     

     

    • SIP Signaling group enabled.

    9

    11

    alarm

    SIP Signaling group: DNS failure

    communication

    SG

    major

    (tick)

    • Failed to resolve the FQDN entries in the SIP Signaling Group. Suggested action - confirm the FQDNs, and confirm DNS access.

    9

    12

    event

    SIP Signaling Group; FQDN resolved

    919event

    communication

    SG

     

     

    • Successfully
    • resolved the FQDN of the SIP Signaling group.

    9

    13

    alarm

    SIP

    Server; DNS failure.

    communication

    SIPCluster;ServID

    major

    (tick)

    • Failed to resolve the SIP
    • server FQDN entries in the SIP Server table.
    • Suggested action - check the FQDN syntax.

    9

    14

    event

    SIP

    Server

    ; FQDN resolved

    communication

    SIPCluster;ServID

     

     

    • SIP
    • Server config FQDN resolved.

    9

    2215

    alarmRegistration not valid; received stale=false

    SIP call session DNS failure

    communication

    SIPCluster;ServID;Protocol;IPAddress;PortSG

    major

    (tick)

     

    • Failed to resolve an FQDN with DNS server during a SIP call session.Server has sent stale=false. Contact is not Registered.

    9

    2316

    eventalarm

    Config change for SIP endpoint that received stale=falseAcquiring license for Register failed

    communication

    SG;AorName

     major

     

    • Endpoint which had Stale is False has config changeFailed to acquire license from License Manager.
    917alarmSession leak or some other resource leakcommunication

    SIPCluster;ServID;Protocol;IPAddress;Port

    minor

    (tick)

    • QoE Notify Message Response was not successful”/” QoE Notify Message received a no response or a failed response. This alarm is cleared by the event 'QoE Notify Message received a successful response'.”

    9

    25

    event

    SGmajor 
    • SIP performs self-check for leaks. Please enable logging for sip and issue "show resources" command.
    918alarmFailed to bind to network interfacecommunicationSGminor

    (tick)

    • QOE Notify Message received a successful response.

    9

    26

    alarm

    SIP overload detected

    communication

    System;Service

    minor

    (tick)

     

    • Failed to bind to network interface due to dynamic IP address not available.
    919eventSuccessfully bound to network interfacecommunicationSG  
    • Successfully bound to network interface. DHCP lease renewed.
    920alarmSIP Register Server not respondingcommunication

    SG

    minor

    (tick)

    SIPCluster;ServID;Protocol;IPAddress;Portmajor

    (tick)

    • SIP Register server has failed to respond. This alarm will be cleared by the event "SIP Regular server became responsive".
    921eventSIP Register Server became  unresponsivecommunicationSIPCluster;ServID;Protocol;IPAddress;Port  
    • SIP
    • Register server came up.

    9

    3022

    alarmError resolving SRV record

    Registration not valid; received stale=false

    communication

    SIPCluster;ServID;Protocol;IPAddress;Port

    major

    (tick)

    • Failed to execute SRV record query. Suggested action - confirm that DNS server network is reachable, check SRV and DNS server configurationServer has sent stale=false. Contact is not Registered.

    9

    3123

    eventSRV record resolved

    Config change for SIP endpoint that received stale=false

    communication

    SIPClusterSG;ServIDAorName

    none 

     

    • DNS server returned valid SRV record(s)Endpoint which had Stale is False has config change.

    9

    24

    alarm

    SIP-TLS Handshake Negotiation Start FailuresecurityTLSProfile;IPAddresscritical(tick)
    • Handshake failed due to start with invalid certificate. Action: Import a valid signed Sonus SBC Certificate on local and/or remote gateway.
    933eventSIP-TLS Handshake Negotiation Start SuccessfulsecurityTLSProfile;IPAddressnone(tick)
    934eventMaximum supported SIP SGs reachedGeneralSystem;Servicewarning(tick)
    • SIP signaling group count reached maximum supported limit.
    935eventMaximum supported SIP SGs cleared

    General

    System;Servicenone 
    • SIP signaling group count is under the maximum supported
    936alarmMaximum non-SIP call sessions reachedGeneralSystem; Servicewarning(tick)
    • Number of SIP non-call sessions is over the system capacity
    937eventMaximum non-SIP call Sessions clearedGeneralSystem:Servicenone 
    • Number of SIP non-call sessions is under the system capacity
    938alarmMaximum SIP call sessions reachedGeneralSystem;Servicewarning(tick)
    • Number of SIP call sessions is over the system capacity
    939eventMaximum SIP call sessions clearedGeneralSystem.Servicenone 
    • Number of SIP call sessions is under the system capacity
    940AlarmBroadsoft SIP call re-routedGeneralSGwarning(tick)
    • Broadsoft SIP call re-routed
    941eventBroadsoft SIP Call Re-routed clearedGeneralSGnone 
    • Number of SIP Call Sessions is under the system capacity.
    942alarmSIP SG Listen Protocol and SIP Server Host Protocol mismatchProcessingSIPCluster;ServerIDminor 
    • Verify that the listen ports and protocols for the SG match those in the server table.
    943alarmConfiguration Error: SIP SG and Server Protocol MismatchProcessingSIPCluster;ServerIDmajor 
    • Verify that the listen ports and protocols for the SG match those in the server table.
    944alarmSIP-TLS Client Handshake FailureSecurityTLSProfile;IPAddressminor(tick)
    • TLS client handshake failed with alert code. Action: Refer to Error Alerts in RFC 5246 for the problem.
    945eventSIP-TLS Handshake Inactivity Timeout ClosedSecurityTLSProfile;IPAddress  
    • Handshake response was received within specified timeout. This event clears the 'SIP-TLS Handshake Inactivity Timeout Failure' alarm.
    946eventSIP-TLS Server Handshake Failure ClearedSecurityTLSProfile;IPAddress  
    • Handshake failure error alert condition was cleared. This event clears the 'SIP-TLS Server Handshake Failure' alarm.
    947eventSIP-TLS Client Handshake Failure ClearedSecurityTLSProfile;IPAddress  
    • Handshake failure error alert condition was cleared. This event clears the 'SIP-TLS Client Handshake Failure' alarm.
    948alarmSkype/Lync Presence Response FailurecommunicationSIPCluster; ServIdminor(tick)

    QoE Notify Message was not successful

    communication

    SIPCluster;ServID;Protocol;IPAddress;Port

    minor

    (tick)

    • QoE Notify Message Response was not successful”/” QoE Notify Message received a no response or a failed response. This alarm is cleared by the event 'QoE Notify Message received a successful response'.”

    9

    25

    event

    QoE Notify Message Response was successful

    communication

    SG

     

    (tick)

    • QOE Notify Message received a successful response.

    9

    26

    alarm

    SIP overload detected

    communication

    System;Service

    minor

    (tick)

    • SIP application session processing is overloaded.

    9

    27

    event

    SIP overload cleared

    communication

    System;Service

     

     

    • SIP application session processing resumes to normal operation, overload cleared.

    9

    28

    alarm

    SIP maximum sessions per SG reached

    communication

    SG

    minor

    (tick)

    • The maximum number of SIP sessions (calls/register/subscribe) has been reached on the signaling group. Increase the number of SIP Channels for the signaling group.

    9

    29

    event

    Maximum Number of SIP Sessions Alarm Cleared

    communication

    SG

     

     

    • SIP sessions per signaling group is under the maximum limit.

    9

    30

    alarm

    Error resolving SRV record

    communication

    SIPCluster;ServID

    major

    (tick)

    • Failed to execute SRV record query. Suggested action - confirm that DNS server network is reachable, check SRV and DNS server configuration.

    9

    31

    event

    SRV record resolved

    communication

    SIPCluster;ServID

    none

     

    • DNS server returned valid SRV record(s).
    932alarmSIP-TLS Handshake Negotiation Start FailuresecurityTLSProfile;IPAddresscritical(tick)
    • Handshake failed due to start with invalid certificate. Action: Import a valid signed Sonus SBC Certificate on local and/or remote gateway.
    933eventSIP-TLS Handshake Negotiation Start SuccessfulsecurityTLSProfile;IPAddressnone(tick)
    • Handshake response was started with valid certificate on local and remote gateway. This event clears the 'SIP-TLS Handshake Negotiation Start Failure' alarm.
    934eventMaximum supported SIP SGs reachedGeneralSystem;Servicewarning(tick)
    • SIP signaling group count reached maximum supported limit.
    935eventMaximum supported SIP SGs cleared

    General

    System;Servicenone 
    • SIP signaling group count is under the maximum supported
    936alarmMaximum non-SIP call sessions reachedGeneralSystem; Servicewarning(tick)
    • Number of SIP non-call sessions is over the system capacity
    937eventMaximum non-SIP call Sessions clearedGeneralSystem:Servicenone 
    • Number of SIP non-call sessions is under the system capacity
    938alarmMaximum SIP call sessions reachedGeneralSystem;Servicewarning(tick)
    • Number of SIP call sessions is over the system capacity
    939eventMaximum SIP call sessions clearedGeneralSystem.Servicenone 
    • Number of SIP call sessions is under the system capacity
    940AlarmBroadsoft SIP call re-routedGeneralSGwarning(tick)
    • Broadsoft SIP call re-routed
    941eventBroadsoft SIP Call Re-routed clearedGeneralSGnone 
    • Number of SIP Call Sessions is under the system capacity.
    942alarmSIP SG Listen Protocol and SIP Server Host Protocol mismatchProcessingSIPCluster;ServerIDminor 
    • Verify that the listen ports and protocols for the SG match those in the server table.
    943alarmConfiguration Error: SIP SG and Server Protocol MismatchProcessingSIPCluster;ServerIDmajor 
    • Verify that the listen ports and protocols for the SG match those in the server table.
    944alarmSIP-TLS Client Handshake FailureSecurityTLSProfile;IPAddressminor(tick)
    • TLS client handshake failed with alert code. Action: Refer to Error Alerts in RFC 5246 for the problem.
    945eventSIP-TLS Handshake Inactivity Timeout ClosedSecurityTLSProfile;IPAddress  
    • Handshake response was received within specified timeout. This event clears the 'SIP-TLS Handshake Inactivity Timeout Failure' alarm.
    946eventSIP-TLS Server Handshake Failure ClearedSecurityTLSProfile;IPAddress  
    • Handshake failure error alert condition was cleared. This event clears the 'SIP-TLS Server Handshake Failure' alarm.
    947eventSIP-TLS Client Handshake Failure ClearedSecurityTLSProfile;IPAddress  
    • Handshake failure error alert condition was cleared. This event clears the 'SIP-TLS Client Handshake Failure' alarm.
    948alarmSkype/Lync Presence Response FailurecommunicationSIPCluster; ServIdminor(tick)

    A Presence Publish Request has been sent to the configured Skype/Lync Presence Front End and either:

      • no response has been received, or
      • the response failed.

    Only one alarm is raised at any time. The alarm is cleared when the SIP presence entity receives a successful response to a Publish message.

    949alarmSkype/Lync Presence Server has become responsivecommunicationSIPCluster; ServIdminor(error)

    The SBC has received a message from a previously unreachable presence server.

    950alarmSIP Request from Untrusted IPSecurityIPAddressminor 
    • An INVITE message was received from a host without a matching Federated IP.
    951alarm(no longer used)     
    952alarmResync message received on SG, not selected for Auto Configuration task.ProcessingSGmajor 
    • Check Auto configuration Task settings and verify that the Signaling Group selected is correct.
    953alarmMaximum Number of Skype/Lync Presence Sessions ReachedcommunicationSGminor(tick)

    The maximum number of 500 concurrent SIP Publish sessions for Presence has been reached. Skype/Lync Presence processing will be suspended until the number of concurrent sessions drops below 500 limit.

    This alarm is raised if:

    • The connection to Nectar UCD server is broken
    • VQ Notify is rejected by Nectar UCD server.
    • The Nectar UCD's FQDN is not resolved by DNS server.

    The active alarm gets cleared when NOTIFY is accepted by Nectar UCD successfully.

    954eventMaximum Number of S4B Presence Publish Sessions Alarms ClearedcommunicationSG (tick)
    • SIP Publish sessions for S4B Presence is under the maximum limit.
    955alarmEnable Monitoring on Skype Presence Server for better reliabilitycommunicationSIPClusterminor(tick)
    • Enable Monitoring on Skype Presence Server for better reliability.
    956eventMonitoring on Skype Presence Server has been enabledcommunicationSIPCluster  
    • Monitoring the Skype Presence Server has been enabled.
    957alarmThe SIP voice Quality Server Connection is BrokencommunicationProtocol;IPAddress;Portmajor(tick)
    • Suggested Action: Verifying the IP, Port, Protocol, and Certificate (if TLS) are Correct.
    958eventThe SIP Voice Quality Server Connection is ResumedcommunicationProtocol;IPAddress;Port  
    • The SIP Voice Quality Server Connection is Resumed
    959alarmThe Voice Quality Nofiy Rejected by the SIP Voice Quality ServercommunicationIPAddress;Portwarning(tick)
    • Suggested Action: Examining the Notify Response Code and the Reason Header (if included) to understand why it was rejected.
    960alarmThe Voice Quality Notify Accept by the SIP Voice Quality ServercommunicationIPAddress;Port  
    • The Voice Quality Notify has been Accept by The SIP Voice Quality Server.
    961alarmFailed to Resolve the FQDN of the SIP Voice Quality ServercommunicationIPAddresswarning 
    • Failed to Resolve FQDN of the SIP Voice Quality Server. Suggested action - confirm the DNS access and FQDN.
    962eventThe SIP Boice Quality Server FQDN has been ResolvedcommunicationIPAddress  
    • The SIP Boice Quality Server FQDN has been Resolved
    949alarmSkype/Lync Presence Server has become responsivecommunicationSIPCluster; ServIdminor(error)

    The SBC has received a message from a previously unreachable presence server.

    950alarmSIP Request from Untrusted IPSecurityIPAddressminor 
    • An INVITE message was received from a host without a matching Federated IP.
    951alarmSIP Request from Untrusted IP clearedGeneralIPAddressmajor 
    • Source IP is added to the list of federated IP addresses.
    952alarmResync message received on SG, not selected for Auto Configuration task.ProcessingSGmajor 
    • Check Auto configuration Task settings and verify that the Signaling Group selected is correct.
    953alarm SIP critical(tick)

    This alarm is raised if:

    • The connection to Nectar UCD server is broken
    • VQ Notify is rejected by Nectar UCD server.
    • The Nectar UCD's FQDN is not resolved by DNS server.
    The active alarm gets cleared when NOTIFY is accepted by Nectar UCD successfully.

    ISDN

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    10

    1

    alarm

    D-Channel down

    communication

    Card;Port

    critical

    (tick)

    • The data link layer of the port has come down.

    10

    2

    event

    D-Channel up

    communication

    Card;Port

     

     

    • The data link layer of the port has come back up.

    10

    3

    alarm

    Call released due to channel restart by far end

    communication

    Card;Port;Channel

    minor

     

    • Call released as the ISDN channel has been restarted by far end.

    Telco Interface Process

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    11

    1

    alarm

    Port disabled by operator

    communication

    Card;Port

    major

    (tick)

    • The physical layer of the port has been brought down by the operator.

    11

    2

    event

    Port enabled by operator

    communication

    Card;Port

     

     

    • The physical layer of the port has been brought back up by the operator.

    11

    3

    alarm

    DS1 Loopback Enter

    communication

    Card;Port

    critical

    (tick)

    • The DS1 has been put into a loopback state by the operator.

    11

    4

    event

    DS1 Loopback Exit

    communication

    Card;Port

     

     

    • The DS1 has been taken out of the loopback state by the operator.

    11

    5

    alarm

    Red Alarm - Loss of Signal

    communication

    Card;Port

    critical

    (tick)

    • The physical layer has detected a Red (LOS) alarm.

    11

    6

    event

    Red Alarm - Loss of Signal cleared

    communication

    Card;Port

     

     

    • The physical layer has detected a Red (LOS) alarm clearing.

    11

    7

    alarm

    Red Alarm - Loss of Frame

    communication

    Card;Port

    critical

    (tick)

    • The physical layer has detected a Red (LOF) alarm.

    11

    8

    event

    Red Alarm - Loss of Frame cleared

    communication

    Card;Port

     

     

    • The physical layer has detected a Red (LOF) alarm clearing.

    11

    9

    alarm

    Blue Alarm

    communication

    Card;Port

    critical

    (tick)

    • The physical layer has detected a blue alarm.

    11

    10

    event

    Blue Alarm Cleared

    communication

    Card;Port

     

     

    • The physical layer has detected an alarm clearing.

    11

    11

    alarm

    Yellow Alarm

    communication

    Card;Port

    critical

    (tick)

    • The physical layer has detected an yellow alarm.
    • This can be originated because of an alarm assert issued by operator or a detection of alarm condition from far end.

    11

    12

    event

    Yellow Alarm Cleared

    communication

    Card;Port

     

     

    • The physical layer has detected an yellow alarm clear.

    11

    13

    alarm

    Port disabled as port not found on DS1

    communication

    Card;Port

    critical

     

    • This alarm is generated to indicate that a port which was present in the UI is now marked as disabled because the corresponding port was not present on the DS1 physical hardware.

    11

    14

    alarm

    Clock recovery switched to port configured as secondary

    communication

    System

    critical

    (tick)

    • This alarm is generated to indicate that the primary port from which clock was being recovered has gone down and so clock recovery is now being performed on the secondary port.

    11

    15

    event

    Clock recovery switchover to secondary port cleared

    communication

    System

     

     

    • This event is generated to indicate that the primary port from which clock was being recovered is back in operation and so clock recovery is now being performed on the primary port.

    11

    16

    alarm

    Clock recovery switched to freerun clock

    communication

    System

    critical

    (tick)

    • This alarm is generated to indicate that the primary and secondary ports from which clock was being recovered have gone down and so clock recovery is now being performed internally from oscillator holdover clock.

    11

    17

    event

    Clock recovery switchover to freerun clock cleared

    communication

    System

     

     

    • This event is generated to indicate that either the primary or secondary port from which clock was being recovered is back in-service, so clock will be recovered from the in-service port instead of the oscillator holdover clock.

    11

    18

    alarm

    Line card not detected

    communication

    Card

    warning

    (tick)

    • Line card not detected.

    11

    19

    event

    Line card detected

    communication

    Card

     

     

    • Line card detected.

    11

    20

    alarm

    Port disabled for relay passthrough state activation

    communication

    Card;Port

    warning

    (tick)

    • Port disabled because the corresponding port is activated for relay passthrough state.

    11

    21

    event

    Port enabled for relay online state activation

    communication

    Card;Port

     

     

    • Port enabled because the corresponding port is re-activated for relay online state.

    11

    22

    alarm

    Layer 1 down

    communication

    Card;Port

    critical

    (tick)

    • The physical layer has detected layer 1 down due to state conditions that results in non-operational state of the BRI port.
    • The physical layer state as per I.
    • 430 specification can be found in the UI Port View for troubleshooting.

    11

    23

    event

    Layer 1 up

    communication

    Card;Port

     

     

    • The physical layer 1 down alarm is cleared with operational state of the BRI port.

    11

    24

    alarm

    Port disabled as port not found on analog card

    communication

    Card;Port

    critical

     

    • Port is now marked as disabled because the corresponding port was not present on the analog physical hardware.

    11

    25

    alarm

    Ports disabled for relay pass through state change on analog relay card pairs

    communication

    System;Card;Card

    warning

    (tick)

    • Ports are now marked as disabled for activated relay passthrough state on analog FXS/FXO card pair.

    11

    26

    event

    Ports enabled for relay online state change on analog relay card pairs

    communication

    System;Card;Card

     

     

    • Ports are now marked as enabled for activated relay passthrough state on analog FXS/FXO card pair.

    11

    27

    alarm

    Port status down detected

    communication

    Card;Port

    warning

    (tick)

    • Line down condition detected.

    11

    28

    event

    Port status up

    communication

    Card;Port

     

     

    • Line down condition cleared.

    11

    29

    alarm

    Port disabled as port not found on BRI

    communication

    Card;Port

    critical

     

    • This alarm is generated to indicate that a port which was present in the UI is now marked as disabled because the corresponding port was not present on the BRI physical hardware.

    11

    30

    alarm

    System not operational

    communication

    System

    critical

     

    • System not operational because DSP cannot be initialized.
    • Contact Sonus TAC with the information in this alarm.
    1131alarmDS1 sync failurecommunicationCard;Portcritical(tick)DS1 sync failure could be due to mismatching line configuration. Suggested Action: Disable "Admin State" of unused ports to avoid performance impact.
    1132eventDS1 sync failure clearedcommunicationCard;Port  DS1 sync failure cleared.

    Media Stream Controller

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    12

    1

    alarm

    DSP not coming up

    equipment

    DSP

    critical

    (tick)

    • This alarm will be generated if a DSP cannot be initialized.
    • If the DSP does not come up, contact Sonus TAC with the information in this alarm.

    12

    2

    alarm

    DSP reset

    equipment

    DSP

    major

    (tick)

    • This alarm will be generated if a DSP encounters a fatal error condition and has to be reinitialized.

    12

    3

    event

    DSP Card is UP

    equipment

    Card

     

     

    • This event will clear the 'DSP not coming up' and 'DSP reset' alarms.

    12

    4

    event

    DSP Channel Failure

    processing

    Card;Port;Channel

     

     

    • This event will be generated if a DSP channel encounters a fatal error condition and has to be closed.
    125alarmRTP/RTCP Port Range InvalidequipmentSystemcritical(tick)
    • This alarm is generated if a RTP/RTCP port is found to be invalid. The conflicting port is skipped, however, this condition should be resolved by reconfiguring the RTP/RTCP Port Range under Media System Configuration.
    126eventRTP/RTCP Port Range Invalid ClearedequipmentSystem  
    • This event will clear the "RTP/RTCP Port Range Invalid" alarm.
    127alarmMSC Media Stream Mode MismatchgeneralSystem;Serviceminor 
    • This alarm is generated when there is a mismatch in media stream mode of the two call legs. Suggested action: match "Audio/Fax Stream Mode" settings and clear alarm.
    128alarmMusic-On-Hold failed due to improperly configured source.communicationSystem;Serviceminor 
    • Music-On-Hold enabled; source is not properly configured. If source is set to file: upload a file, disable music on hold or switch source to an FXS port.

    Certificate Security Manager

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    13

    1

    alarm

    TLS Own Server Certificate will Expire

    security

    CertificateCommonName

    major

    (tick)

    • The Server certificate will expire in a window time.
    • Suggested Action: Generate, Export CSR and Import a new signed certificate.

    13

    2

    alarm

    TLS Own Server Certificate has Expired

    security

    CertificateCommonName

    critical

    (tick)

    • The Server certificate has expired.
    • Suggested Action.
    • Generate, Export CSR and Import a new signed certificate.

    13

    4

    alarm

    TLS Self Sign Certificate Generation Failed

    security

    CertificateCommonName

    critical

     

    • Failed to create a default self signed certificate on the system.

    13

    5

    event

    New and Valid TLS Own Server Certificate Detected

    security

    CertificateCommonName

     

     

    • The Server certificate was uploaded, validated, and good to use in successfully establishing a TLS connection.

    13

    6

    alarm

    TLS Trusted Certificate Authority will Expire

    security

    CertificateCommonName

    major

    (tick)

    • The Trusted CA Certificate will expire in a window time. Suggested Action: Import a new trusted CA certificate.

    13

    7

    alarm

    TLS Trusted Certificate Authority has Expired

    security

    CertificateCommonName

    critical

    (tick)

    • The Trusted CA Certificate has expired. Import a new trusted CA certificate.

    13

    8

    event

    TLS Trusted Certificate Authority was Deleted

    security

    CertificateCommonName

     

     

    • The Trusted Certificate Authority is successfully deleted due to the expired or expiring soon validity status.
    139alarmTLS Own Server Certificate Expiry NoticesecurityCertificateCommonNameminor(tick)
    • The Server certificate will expire in a window time. Suggestion Action: Generate, Export CSR and Import a new signed certificate.
    1310alarmTLS Trusted Certificate Authority Expiry NoticesecurityCertificateCommonNameminor(tick)
    • The Trusted CA certificate will expire in a window time. Suggestion Action: Import a new trusted CA certificate.

    BMP

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    14

    1

    alarm

    Invalid Session for attempted realtime connection

    security

    IPAddress

     

     

    • Invalid Session for attempted realtime connection.

    14

    2

    alarm

    BMP-TLS Handshake Alert Failure

    security

    IPAddress

    minor

     

    • This alarm will be generated if TLS Connection failed with an Alert.
    • The connection associated with a TLS Connection ID is aborted.

    14

    3

    alarm

    BMP-TLS Handshake Inactivity Timeout Failure

    security

    IPAddress

    minor

     

    • This alarm will be generated if there was long period of inactivity during exchange of handshake messages for an associated TLS Connection ID.

    Network Services

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    15

    1

    alarm

    Interface oper down

    communication

    Port

    major

    (tick)

    • Occurs when an Ethernet port (of ports 1, 2, 3 and 4) is operationally down (e.g. cable unplugged, mismatched speed/duplexity settings) and if admin-status is ADMIN_UP.
    • The alarm is automatically cleared when the interface returns to working condition or when the admin-status is configured to be ADMIN-DOWN.
    • Is generated only on Sonus SBC 2000 platform.
    • This alarm is not generated on the Sonus SBC 1000 platform (See ID: 15, Sub-ID: 7 in this table).
    • The operator should check the physical cabling of the port that has this condition and verify the speed and duplexity settings on Sonus SBC 1000/2000 and on the device connected to the other end of the Ethernet cable.
    • If the alarm is reported on an unused port, the admin-status of the unused port should be configured as "ADMIN-DOWN".

    15

    2

    event

    Interface oper up

    communication

    Port

     

     

    • Is generated when an Ethernet port (of ports 1, 2, 3 and 4) becomes operationally up.
    • This event automatically clears the "Interface oper down" alarm.

    15

    3

    event

    Interface admin up

    communication

    LogicalInterface

     

     

    • Is generated when the admin-status of the Port or Logical Interface is configured to be ADMIN-UP.
    • Is applicable to Sonus SBC 2000 platform only.

    15

    4

    event

    Interface admin down

    communication

    LogicalInterface

     

     

    • Is generated when the admin-status of the Port or Logical Interface is configured to be ADMIN-DOWN.
    • Is applicable to Sonus SBC 2000 platform only.

    15

    5

    event

    Admin Port oper down

    communication

    Port

     

     

    • Is generated when the Admin Port is operationally down (e.g. cable unplugged, mismatched duplex/speed settings).
    • Is applicable to Sonus SBC 2000 platform only.
    • The operator should check the physical cabling of the port that has this condition and verify the speed and duplexity settings on Sonus SBC 1000/2000 and on the device connected to the other end of the Ethernet cable.
    • It is very common and typical for Sonus SBC 2000 to leave the ADMIN-PORT unconnected and hence this condition is reported as an event and not an alarm.

    15

    6

    event

    Admin Port oper up

    communication

    Port

     

     

    • Is generated with the port becomes operational after being in an *Admin port oper down* state.
    • Is applicable to Sonus SBC 2000 platform only.

    15

    7

    event

    Port oper down

    communication

    Port

     

     

    • Occurs when an Ethernet port (of ports 1 and 2) is operationally down (e.g. cable unplugged, mismatched speed/duplexity settings).
    • Is generated only on Sonus SBC 1000 platform.
    • The same conditions are reported as alarm (ID: 15, Sub-ID: 1) on Sonus SBC 2000 platform.
    • When this event occurs (noticed as a trap), operator should check the physical cabling of the port that has this condition and verify the speed and duplexity settings on Sonus SBC 1000/2000 and on the device connected to the other end of the Ethernet cable.

    15

    8

    event

    RIP license not enabled

    communication

    System

     

     

    • RIP feature license is not enabled.

    15

    9

    event

    OSPF license not enabled

    communication

    System

     

     

    • OSPF feature license is not enabled.

    15

    10

    alarm

    Link Monitor Peer down

    communication

    IPAddress

    major

    (tick)

    • Generated when a Gateway or host is declared down.

    15

    11

    event

    Link Monitor Peer ready

    communication

    IPAddress

    event

    (tick)

    • Is generated when a gateway or host is ceclared to be ready for service. It clears the Peer Down alarm.

    15

    12

    event

    Tunnel connection disabled by operator

    communication

    NetworkName

     

     

    • Tunnel connection is placed Out of Service by operator.

    15

    13

    event

    Tunnel connection enabled by operator

    communication

    NetworkName

     

     

    • Tunnel connection is placed Back in Service by operator.

    15

    14

    alarm

    Tunnel Link Lost

    communication

    NetworkName

    critical

    (tick)

    • Tunnel lost communication with the peer. This alarm will be cleared by the "Tunnel link restored" event.

    15

    15

    event

    Tunnel Link Restored

    communication

    NetworkName

     

     

    • Tunnel is successfully re-established with the peer.

    15

    16

    event

    IPsec license not enabled

    communication

    System

     

     

    • IPsec license is not enabled.

    15

    17

    alarm

    Negotiated  Duplexity Half

    communication

    Port

    warning

    (tick)

    • Port negotiated duplexity is half. This degrades the performance.

    15

    18

    event

    Negotiated Duplexity Full

    communication

    Port

     

     

    •  Port negotiation duplexity is back to full.

    15

    19

    alarm

    Preferred Link down

    communication

    IP address

    critical

    (tick)

    • Is generated when the preferred Link is down.

    15

    20

    event

    Preferred Link Ready

    communication

    IP address

    event

     

    • Is generated when the preferred link is ready for service. This clears the Preferred Link down alarm.

    15

    21

    alarm

    Tunnel Notification failure

    communication

    NetworkName

    critical

     

    • Is generated when Tunnel negotiation failed.

    15

    22

    event

    Tunnel local subnet(s) are non-negotiable

    communication

    NetworkName

    event

     

    • Is generated when one or more local subnet(s) failed negotiation as a result of peer config mismatch.

    15

    23

    event

    Tunnel remote subnet(s) are non-negotiable

    communication

    NetworkName

    event

     

    • Is generated when one or more remote subnet(s) failed negotiation as a result of peer config mismatch.
    1524eventPort State LearningcommunicationMSTPInstance;Portevent 
    • Is generated when a Port State is Learning in a Multiple Spanning Tree Instance.
    1525eventPort State ForwardingcommunicationMSTPInstance;Portevent 
    • Is generated when a Port State is Forwarding in a Mulitple Spanning Tree Instance.
    1526eventPort State DiscardingcommunicationMSTPinstance;Portevent 
    • Is generated when a Port State is Discarding in a Multiple Spanning Tree Instance.
    1527alarmPacket Capture StartedgeneralSystemwarning 
    • Packet capture has started.
    1528eventPacket Capture StoppedgeneralSystem  
    • Packet capture has stopped due to 'reason'.
    1529alarmDuplicate IPv6 address detectedcommunicationInterface;IPAddresscritical 
    • Is generated when duplicate address detection fails for a configured IPv6 address.
    1530eventIP address configuredcommunicationInterface;IPaddress  
    • Is generated when an IP address is configured on the node.
    1531eventIP address removedcommunicationInterface;IPaddress  
    • Is generated when an IP address is removed from the node.

    System Health Monitor

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    16

    1

    alarm

    Application Service restarted

    processing

    Service

    major

     

    • A Sonus SBC 1000/2000 Application service was restarted.

    16

    2

    alarm

    Active partition switched

    processing

    Partition

    major

     

    • System detected a problem during previous boot cycle, active partition has switched automatically.
    • Suggested action - backup the configuration and re-apply the upgrade to the currently inactive partition.

    16

    3

    alarm

    Failed to mount partition

    processing

    Partition

    major

     

    • While booting, one of the partition could not be mounted.
    • Likely a eUSB corruption.
    • Contact Sonus TAC with the information in this alarm.

    16

    4

    alarm

    Failed to set active partition

    processing

    Partition

    major

     

    • Failed to set active partition.
    • Contact Sonus TAC with the information in this alarm.

    16

    5

    alarm

    Attempt to repair boot parameter mismatch failed.

    processing

    Partition

    major

     

    • Attempt to auto repair boot parmeters failed.
    • Contact Sonus TAC with the information in this alarm.

    16

    6

    alarm

    Failed to mount partition

    processing

    Partition

    major

     

    • Boot parameter mismatch was detected.
    • Attempting to auto repair.

    16

    7

    alarm

    Failed Power-on memory self test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    8

    alarm

    Failed Power-on Core Switch test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    9

    alarm

    Failed Power-on Secondary Switch test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    10

    alarm

    Failed Power-on external Quad PHY test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    11

    alarm

    Failed Power-on external Single PHY test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    12

    alarm

    Failed Power-on CPU PHY test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    13

    alarm

    Failed Power-on TSI test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    14

    alarm

    Failed Power-on internal 5-Port PHY test

    equipment

    Partition

    critical

     

    • Power-on self test failure.

    16

    15

    event

    System Up After Planned Restart

    equipment

    System

     

     

    • System up after planned restart

    16

    16

    alarm

    System Up After Unplanned Restart

    equipment

    System

    major

     

    • System up after unplanned restart.
    1617alarmEntered password recovery modesecuritySystemmajor 
    • SBC has entered password recovery mode.
    1618eventExited password recovery modesecuritysystem  
    • SBC has exited password recovery mode.
    1619alarmFailed to mount USB storage deviceequipmentSystem;Servicemajor 
    • SBC discovered USB storage. SBC can mount flash drives formatted with FAT32 file system only.
    1620eventUSB storage device connectedequipmentSystem;Service  
    • USB storge device is connected.
    1621AlarmUSB storage device disconnectedequipmentSystem;Servicewarning 
    • USB storge device is disconnected. This alarm is cleared when USB drive is connected.
    1622AlarmCritical application crashalmProcessingServicecritical 
    • A Critical Sonus SBC application has crashed, system will be restarted. Contact Sonus TAC with the information in this alarm and all core files present on the system. Core files can be found in Diagnostics->Restart Report under the 'Core Files' tab. 
    1623AlarmOlder firmware detectedprocessingSystem;Servicecritical 
    • A USB firmware update is available. To perform upgrade, please first load SW release v4.1.1.
    1624EventAuto Configuration successfulequipmentSystem;Service  
    • Auto Configuration successful after receiving SIP NOTIFY message.
    1625AlarmAuto Configuration failedprocessingSystem;Servicemajor 
    • Failed to perform Auto Configuration after receiving SIP NOTIFY messageSIP NOTIFY message.
    1626AlarmSoftware Update in progressprocessingSystem;Servicemajor 
    • Current SIP NOTIFY message cannot be processed as software update is in progress.
    1627AlarmNode RebootequipmentServiceminor 
    • Node Reboot requested by user "Username" from "IP Address".
    162628AlarmSoftware Update in progressprocessingFactory DefaultequipmentSystem;Servicemajor 
    • Current SIP NOTIFY message cannot be processed as software update is in progressFull factory default requested by user "Username" from "IP Address".

    CAS

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    17

    1

    alarm

    No response

    communication

    Card;Port;Channel

    major

    (tick)

    • No response to seizure.

    17

    2

    alarm

    Remote end did not back off in glare

    communication

    Card;Port;Channel

    minor

     

    • Remote end did not back off in glare.

    17

    3

    alarm

    Wink expected, did not arrive

    communication

    Card;Port;Channel

    major

    (tick)

    • Wink expected, did not arrive.

    17

    4

    alarm

    No dial tone

    communication

    Card;Port;Channel

    major

    (tick)

    • Event of off-hook did not produce dial tone as expected.

    17

    5

    event

    CAS signaling group disabled

    communication

    SG

     

    (tick)

    • CAS signaling group disabled.

    17

    6

    alarm

    CAS license not enabled

    general

    System;Service

    major

    (tick)

    • Call attempted but CAS feature is not enabled.
    • This alarm is cleared by CAS license enabled event.

    17

    7

    event

    CAS license enabled

    general

    System;Service

     

     

    • License manager notify CAS that license is enabled.

    17

    8

    event

    Wink Received

    communication

    Card;Port;Channel

     

     

    • Wink failure had occurred, but wink is received now.

    17

    9

    event

    Dial Tone Received

    communication

    Card;Port;Channel

     

     

    • No Dial Tone was received, but Dial Tone is received now.

    17

    10

    event

    Response Received

    communication

    Card;Port;Channel

     

     

    • No Response to seizure was received, but Response is received now.

    17

    11

    alarm

    Invalid character(s) in calling number

    communication

    Calling

    warning

     

    • Invalid character(s) removed, correct issue and delete warning.

    17

    12

    alarm

    Invalid character(s) in called number

    communication

    Called

    warning

     

    • Invalid character(s) removed, correct issue and delete warning.

    17

    13

    event

    CAS signaling group enabled

    communication

    SG

     

     

    • CAS signaling group enabled.

    17

    14

    alarm

    CAS-R2 CD Bit error

    communication

    Card;Port

    minor

    (tick)

    • CAS-R2 CD Bits are mismatched.

    17

    15

    event

    CAS-R2 CD Bit error clear

    communication

    Card;Port

     

     

    • CAS-R2 CD Bits are now matching.

    17

    16

    alarm

    Network Glare occured

    communication

    Card;Port;Channel

    minor

     

    • Network glare occured on this interface.

    Configuration

    ID

    Sub-ID

    Type

    Default Condition

    Category

    Decode Key

    Default Severity

    Auto Clear

    Notes/Description

    18

    1

    event

    Config validation failure

    general

    System;Service

    warning

     

    • Config validation failure during startup.
    • Please check the configuration.
    182alarmNewer Config loadedgeneralSystem;Servicewarning 
    • Configuration loaded from newer release than currently running release.
    183eventPassword decryption failedgeneralSystem;Serviceevent 
    • Password decryption failed on configuration import operationfailed on configuration import operation.
    184eventPartial factory defaultequipmentSystem;Serviceevent 
    • Partial "factory default or confiugration import" requested by "Username" from "IP address".
    185eventConfiguration RestoreequipmentSystem;Serviceevent 
    • Configuration restore requested by "Username" from "IP Address".

    TCA Thresholds

    IDSub-IDTypeDefault ConditionCategoryDecode KeyDefault SeverityAuto ClearNotes/Description
    191alarmSG Channel Usage exceeded TCA thresholdcommunicationSGmajor(tick)
    • Signaling Group channel usage exceeded configured TCA threshold.
    192eventSG Channel Usage below TCA thresholdcommunicationSG  
    • Signaling Group channel usage fell below configured TCA threshold.
    193alarmSIP Call License Usage exceeded TCA thresholdcommunicationSystem;Servicemajor(tick)
    • SIP Call license usage exceeded configured TCA threshold.
    194eventSIP Call License Usage below TCA thresholdcommunicationSystem;Service  
    • SIP Call license usage fell below configured TCA threshold.
    195alarmSIP Registration Usage exceeded TCA thresholdcommunicationSIPRegistrarTablemajor(tick)
    • SIP Registration usage exceeded configured TCA threshold.
    196eventSIP Registration Usage below TCA thresholdcommunicationSIPRegistrarTable  
    • SIP Registration usage fell below configured TCA threshold.
    197alarmDSP Usage exceeded TCA thresholdcommunicationSystemmajor(tick)
    • DSP usage exceeded configured TCA threshold.
    198eventDSP Usage below TCA thresholdcommunicationSystem  
    • DSP usage fell below configured TCA threshold.
    199alarmCPU Usage exceeded TCA thresholdcommunicationSystemmajor(tick)
    • CPU usage exceeded configured TCA threshold.
    1910eventCPU Usage below TCA thresholdcommunicationSystem  
    • CPU usage fell below configured TCA threshold.
    1911alarmMemory Usage exceeded TCA thresholdcommunicationSystemmajor(tick)
    • Memory usage exceeded configured TCA threshold.
    1912eventMemory Usage below TCA thresholdcommunicationSystem  
    • Memory usage fell below configured TCA threshold.
    1913alarmFile Descriptor Usage exceeded TCA thresholdcommunicationSystemmajor(tick)
    • File Descriptor Usage exceeded TCA threshold.
    1914eventFile Descriptor Usage below TCA thresholdcommunicationSystem  
    • File Descriptor Usage fell below TCA threshold.
    1915alarmCPU load average in past 1 minute exceeded TCA thresholdcommunicationSystemmajor(tick) 
    • CPU load average in past 1 minute exceeded TCA threshold.
    1916eventCPU load average in past 1 minute fell below TCA thresholdcommunicationSystem   
    • CPU load average in past 1 minute fell below TCA threshold.
    1917alarmCPU load average in past 5 minutes exceeded TCA thresholdcommunicationSystemmajor(tick) 
    • CPU load average in past 5 minutes exceeded TCA threshold.
    1918eventCPU load average in past 5 minutes fell belowTCA thresholdcommunicationSystem   
    • CPU load average in past 5 minutes exceeded TCA threshold.
    1919alarmCPU load average in past 15 minutes exceeded TCA thresholdcommunicationSystemmajor(tick) 
    • CPU load average in past 15 minutes exceeded TCA threshold.
    1920eventCPU load average in past 15 minutes fell belowTCA thresholdcommunicationSystem   
    • CPU load average in past 15 minutes fell below TCA threshold.
    1921alarmTemporary partition usage exceeded TCA thresholdcommunicationSystemmajor(tick) 
    • Temporary partition usage exceeded TCA threshold.
    1922eventTemporary partition usage fell below TCA thresholdcommunicationSystem   
    • Temporary partition usage exceeded TCA threshold.
    1923alarmLogging partition usage exceeded TCA thresholdcommunicationSystemmajor(tick) 
    • Logging partition usage exceeded TCA threshold.
    1924eventLogging partition usage fell below TCA thresholdcommunicationSystem   
    • Logging partition usage fell below TCA threshold.

    FQDN

    IDSub-IDTypeDefault ConditionCategoryDecode KeyDefault SeverityAuto ClearNotes/Description
    201alarmFailed to resolve FQDNcommunicationSNMP;IPAddressminor(tick)
    • Failed to resolve IP Address. Ensure that FQDN and DNS server is configured properly.
    202eventFQDN resolvedcommunicationSNMP;IPAddress  
    • IP Address successfully resolved.

    Decode Key Table

    Following tables defines the decode key types used through out the system Alarms and Events system in Sonus SBC 1000/2000.

    Decode Key

    Description

    System

    By default it will be the Sonus SBC 1000/2000 system

    Service

    Service in which this alarm/event belongs to, for ex. ISDN, SIP etc..

    Username

    Username responsible for the generation of the alarm/event, mostly related to the User Authentication Service

    IP address

    IP address of the system responsible for generation of this alarm/even.

    Frame

    Frame responsible, at which the data transmission has failed/generated an error

    Card/Slot

    Card /Slot involved in generating the alarm For ex. TI DSP etc..

    ActSetTble

    Action set table number responsible for the alarm/event

    NormTble

    Normalization table number responsible for this alarm

    RtTble

    Route table number responsible for this alarm/event

    TLSProfileTLS Profile (ID of the TLS Profile)

    TransTble

    Translation table number responsible for this alarm/event

    Call Dest

    Call destination (address) responsible for this alarm/event

    Conference ID

    Conference ID involved in the alarm generation. It will be an integer starting from 1 to FFFFFFFF

    Codec

    Media codec like G711, used when this alarm is generated

    SG/Signaling Group

    Signaling Group on which this alarm occurred

    Channel

    Channel number that involved in generating this alarm

    CallID

    Call ID of the call failed/is responsible for generating this alarm

    Port

    Port number on which this alarm is generated

    Interface

    Name/Number of the interface involved in generating this alarm. For ex. ETH1, T1 etc..

    Server

    Server responsible for this alarm. for Ex. SIP server which is not responding

    CertificateCommonName

    Server certificate common name for ex:"VeriSign Trial Secure Server CA - G2 "

    SBAInstance

    Its the SBA monitor involved in generating the alarm

    Interface

    By default it will be the Ethernet interface card

    SIPCluster

    Name of the SIP cluster associated with a set of SIP servers

    ServID

    ID of the SIP server

    Protocol

    Protocol involved in generating this alarm/event

    Fan_No

    Fan number