Not supported by SBC SWe Lite in this release.
To add or modify an R2 CAS Profile:
- In the WebUI, click the Settings tab.
- In the left navigation pane, go to CAS > CAS Signaling Profiles.
- From the Create CAS Profile drop down box, select R2 Profile.
Modifying an R2 CAS Profile
- Click the expand () Icon next to the entry you wish to modify.
- Edit the entry properties as required, see details below.
Creating an R2 CAS Profile
- From the Create CAS Profile drop down box at the top of the CAS Signaling Profile Table Page, select R2 Profile.
The RibbonSBC 1000/2000 contains a set of preconfigured Country Profiles that you can apply to an R2 CAS Profile.
To apply a preconfigured profile:
- Click the Apply Country Profile text at the top of the Add CAS R2 Profile panel.
- Select the Country Profile of your choice.
- Click Apply.
R2 Signaling - Field Definitions
Description
Specifies a brief description of the R2 Profile. For example: Basic R2 CAS Profile.
Orientation
Specifies the handling of inbound and outbound call collision.
- User/Slave: inbound call is accepted, outbound call is released.
- Network/Master: the system waits for the remote side to back off.
Incoming Signal Type
Specifies whether the CAS R2 profile uses MF or DTMF signaling for incoming calls. Default entry: MF.
Outgoing Signal Type
Specifies whether the CAS R2 profile uses MF or DTMF signaling for outgoing calls. Default entry: MF.
Line Signaling Options - Field Definitions
CD Bits
Specifies how the C and D bits are transmitted.
Used to specify the setting of the C and D bits transmitted, configured as a bit mask. The value specified is the decimal representation of a 2 bit binary bit mask. For example: to set the 'C' bit to one, binary 10 would be used and entered as 2.
Inverted ABCD Bits
Specifies the inverted A, B, C, or D bits, configured as a bit mask.
Used to specify the inverted A, B, C, or D bits, configured as a bit mask. The line signals are inverted according to this parameter before being transmitted. Received line signals are inverted before being interpreted. The value specified is the decimal representation of a 4 bit binary bit mask. For example: to invert the 'B' bit, binary 0100 would be used and entered as 4.
Meter Code
Specifies whether or not to send a metering signal and how it is implemented.
Metering signals are pulse type signals transmitted backwards during the call from call charging point to subscriber's call meter in the originating exchange.
Release Guard Time
Specifies the release guard time in milliseconds.
Release Guard Time is the interval during which an incoming R2 register waits when a clear forward line signal is received before sending an idle line signal. The value is specified in milliseconds. Zero indicates that the idle signal is to be returned immediately.
Seizure Acknowledgment Timer
Specifies the maximum time, in milliseconds, the outgoing R2 line waits for the seizure acknowledgment signal after sending sending the seizure signal. Zero indicates no time out is to be used.
Inter-Digit Timeout
Used to set the timeout time, in seconds, between dialed numbers. The Ribbon SBC 1000/2000 does not currently support dial plans; the use of an inter-digit timeout is necessary to detect the end of digit dialing.
Register Signaling Options - Field Definitions
Request Calling Party Number
Specifies whether or not the Calling Party Number is requested.
Digits Received Before Request
Specifies the number of DNIS digits received before requesting the ANI. This parameter is not displayed if the Request Calling Party Number is set to Disabled.
Calling Party Number Length
Specifies the number of Called Party Number Digits received before requesting the Calling Party Number. This parameter is displayed only when Request Calling Party Number is set to Enabled.
Calling Party Digits
Specifies the fixed length of the Calling Party Number requested or sent. This parameter is displayed only when Calling Party Number length is set to Fixed.
Called Party Number Length
Specifies whether the length of the Calling Party Number requested or sent is variable or fixed. When variable Calling Party Number length is specified, the Group I-15 signal is used to indicate the end of Calling Party Number. Available only when Request Calling Party Number is set to Enabled.
Called Party Digits
Specifies the length of the expected Called Party Number. This parameter is displayed only when Called Party Number Length is set to Fixed.
Send End of Digit
Specifies whether or not the SBC sends I-15 to indicate the end of digits for the Called Party Number (DNIS). Available entries: Enabled or Disabled. Default entry: Enabled.
Forward Register Signals - Field Definitions
Calling Party's Category
Specifies the Group II forward signal sent after receiving an Address Complete backward signal.
Group III/C Tones - Field Definitions
Use Group-C Tones
Specifies whether the Ribbon SBC 1000/2000 will use the Axtel switch implementation of R2 Group-C tones for Calling Party Number request. Default entry: Disabled.
Forward Register Signals - Field Definitions
Calling Party's Category on A3
Used to specify the Group II calling party's category signal to be sent on receiving the A-3 "Address Complete, Changeover to Group B" backward signal.
Calling Party's Category on Send CPC
Used to specify the Group II calling party's category signal to be sent on receiving "Send Calling Party's Category" backward signal. This parameter is not displayed if the Request Calling Party Number is set to Disabled.
Group-I Tone
Specifies the Group-I tone sent in response to an ANI Request to indicate that ANI is restricted
Group-II Tone (CPC)
Specifies the Group-II tone sent in response to an ANI Category request to indicate that ANI is restricted.
Backward Register Signals - Field Definitions
Send Calling Party's Number
Specifies the the backward group A signal used to request the calling party's number. This parameter is displayed only if the Calling Party Number Request is set to Enabled.
Send Calling Party's Category
Specifies the backward group A signal used to request the calling party's category. This parameter is displayed only if the Calling Party Number Request is set to Enabled.
Address Complete (Changeover to Group B)
Used to specify whether Group B signals are transmitted after the SBC has received address digits. If configured to Yes, the A-3 signal is transmitted to indicate that the SBC does not require additional address digits, and will transmit Group B signal to indicate the condition of the called party. If configured to No, the A-6 signal is transmitted to indicate that the SBC does not require additional address digits, but it will not send a Group B signal.
Send First Address Digit
Specifies the group A backward signal used to request the retransmission of the Called Party Number (starting with the first digit).
Subscriber Line Free Sent
Specifies the group B backward signal sent by the incoming R2 register indicating an idle condition of the destination party.
Subscriber Line Busy Sent
Specifies the group B backward signal sent by the incoming R2 register indicating a busy condition of the destination party.
Congestion Sent
Unallocated Number Sent
Used to specify the group B backward signal sent by the incoming R2 register to indicate that the destination party dialed is unallocated.
Subscriber Line Free Received - Field Definition
Subscriber Line Free Received B1 - B8
Specifies the group B-1 through B-8 backward signal received by the outgoing R2 register for an idle condition of the destination party.
Subscriber LIne Busy Received - Field Definition
Subscriber Line Busy Received B1 - B8
Specifies the group B-1 through B-8 backward signal received by the outgoing R2 register for a busy condition of a destination party.