The following list provides the alarms and events defined for User Authentication and Directory Services.

ID

Sub-ID

Type

MIB Trap NameOID

Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

1

1

Alarm

uxAlmADcachingfailed1.3.6.1.4.1.177.15.2.65537

AD caching failed

Communication

System;Service;IPAddress;PodName;ContainerType

Minor

check mark button 

  • Failed to cache attributes from AD in memory.
  • Suggested action - try again later.
  • This alarm will be cleared by event AD caching successful.

1

2

Event

uxAlmOnlineADqueryfailed1.3.6.1.4.1.177.15.2.65538

Online AD query failed

Communication

System;Service;PodName;ContainerType



  • Failed to run AD query.
  • Suggested action - confirm that AD is network reachable, check the AD configuration as well as AD access credentials.

1

4

Event

uxAlmUserloggedin1.3.6.1.4.1.177.15.2.65540

User logged in

Security

Username;IPAddress;PodName;ContainerType



  • Specified user logged in.

1

5

Alarm

uxAlmUserloginfailed1.3.6.1.4.1.177.15.2.65541

User login failed

Security

Username;IPAddress;PodName;ContainerType

Major

check mark button

  • Specified user login failed on [time] due to [reason].
  • This alarm will be cleared by event User logged in.

1

6

Alarm

uxAlmADUnreachable1.3.6.1.4.1.177.15.2.65542

AD Unreachable

Communication

System;Service;IPAddress;DCType;PodName;ContainerType

Major

check mark button

  • Either AD is network unreachable, or the AD credentials are invalid.
  • This alarm will be cleared by 'AD Reachable' event.

1

7

Event

uxAlmADReachable1.3.6.1.4.1.177.15.2.65543

AD Reachable

Communication

System;Service;IPAddress;DCType;PodName;ContainerType



  • Active directory is now reachable.

1

8

Event

uxAlmADcachingsuccessful1.3.6.1.4.1.177.15.2.65544

AD caching successful

Communication

System;Service;IPAddress;PodName;ContainerType



  • AD caching was successful.

1

9

Alarm

uxAlmADbackupfailed1.3.6.1.4.1.177.15.2.65545

AD backup failed

Equipment

System;Service;IPAddress;PodName;ContainerType

Minor

check mark button

  • Failed to backup cached values from AD to storage device.
  • Either the storage device is not present, or it is full.
  • Contact Ribbon Service for further assistance.

1

10

Event

uxAlmADsuccessfullybackedup1.3.6.1.4.1.177.15.2.65546

AD successfully backed up

Equipment

System;Service;IPAddress;PodName;ContainerType



  • Successful backup of cached values from AD to storage device.

1

11

Alarm

uxAlmADcachetruncated1.3.6.1.4.1.177.15.2.65547

AD cache truncated

Equipment

System;Service;PodName;ContainerType

Minor


  • AD Cache is truncated, AD cache results have exceeded the maximum cache size.
  • Consider caching only the required attributes.
  • If the query is not found in cache, Online query will be performed, while affecting performance.

1

12

Alarm

uxAlmRADIUSServerUnreachable1.3.6.1.4.1.177.15.2.65548

RADIUS Server Unreachable

Communication

System;Service;IPAddress;PodName;ContainerType

Major

check mark button

  • Either the RADIUS server is network unreachable, the configuration is incorrect, or due to service impacting change.
  • Suggested action - check shared secret, listening port, RADIUS server IP.
  • This alarm will be cleared by 'RADIUS Reachable' event.

1

13

Event

uxAlmRADIUSReachable1.3.6.1.4.1.177.15.2.65549

RADIUS Reachable

Communication

System;Service;IPAddress;PodName;ContainerType



  • RADIUS server is online.

1

14

Alarm

uxAlmCDRloggingfailed1.3.6.1.4.1.177.15.2.65550

CDR logging failed

Communication

System;Service;IPAddress;PodName;ContainerType

Major


  • SBC Edge failed to send CDR to RADIUS based accounting server.
  • Either the server is network unreachable, or the configuration is incorrect.
  • Suggested action - check shared secret, listening port, RADIUS server IP.

1

15

Alarm

uxAlmCDRbackupfailed1.3.6.1.4.1.177.15.2.65551

CDR backup failed

Communication

System;Service;IPAddress;PodName;ContainerType

Major


  • SBC Edge failed to backup CDR in local file.
  • Either running with low disk space or CDR backup maximum limit is crossed.
  • Suggested action - Free up the disk space or save the CDR Queued file for future reference.

1

17

Event

uxAlmUserpasswordchangedsuccessfully1.3.6.1.4.1.177.15.2.65553

User password changed successfully

Security

Username;PodName;ContainerType



  • Password changed successfully by [username] from [ipAddress].

1

18

Alarm

uxAlmUserpasswordchangefailed1.3.6.1.4.1.177.15.2.65554

User password change failed

Security

Username;PodName;ContainerType

Warning

check mark button

  • Password change attempted by [username] from [ipAddress] failed.

1

19

Event

uxAlmUseraccountdisabled1.3.6.1.4.1.177.15.2.65555

User account disabled

Security

Username;PodName;ContainerType



  • Account has been disabled by [username] from [ipAddress].

1

20

Event

uxAlmUseraccountactivated1.3.6.1.4.1.177.15.2.65556

User account activated

Security

Username;PodName;ContainerType



  • Account has been activated by [username] from [ipAddress].

1

21

Event

uxAlmGlobalsecurityoptionschanged1.3.6.1.4.1.177.15.2.65557

Global Security Options Changed

Security

Username;IPAddress;PodName;ContainerType



  • Global security options changed.

1

22

Alarm

uxAlmUserloginblocked1.3.6.1.4.1.177.15.2.65558

User login blocked

Security

Username;PodName;ContainerType

Major

check mark button

  • User attempting to log in from [ipAddress] blocked due to excessive incorrect login attempts.

1

23

Event

uxAlmUserloginunblocked1.3.6.1.4.1.177.15.2.65559

User login unblocked

Security

Username;PodName;ContainerType



  • User login is unblocked.
124EventuxAlmUserpasswordexpired1.3.6.1.4.1.177.15.2.65560User password expiredSecurity

Username;IPAddress;PodName;ContainerType



  • Password has expired.
  • User [username] logging in from [ipAddress] password is expired.
125AlarmuxAlmADMaximumThreadsExceeded1.3.6.1.4.1.177.15.2.65561AD: Maximum Threads ExceededProcessing

System;Service;PodName;ContainerType

Major
  • AD has reached maximum threads. Please inform your service representative.
126AlarmuxAlmADcachingtimedout1.3.6.1.4.1.177.15.2.65562AD caching timed outCommunication

System;Service;IPAddress;PodName;ContainerType

Minor
  • Timed out caching attributes due to lack of response from AD.
  • Suggested action - try again later.
  • The SBC will attempt to load the last successful cache from backup.
127AlarmuxAlmADCacheEncryptionFailed1.3.6.1.4.1.177.15.2.65563AD Cache Encryption FailedCommunication

System;Service;IPAddress;PodName;ContainerType

Majorcheck mark button
  • AD Cache encryption failed.
  • Cache will not be saved.
128EventuxAlmADCacheEncryptionSuccessful1.3.6.1.4.1.177.15.2.65564AD Cache Encryption SuccessfulCommunication

System;Service;IPAddress;PodName;ContainerType



AD Cache encryption successful.

129AlarmuxAlmInactivityUserAccountDisable1.3.6.1.4.1.177.15.2.65565Inactivity User Account DisableSecurity

Username;IPAddress;PodName;ContainerType    

Warning

cross mark

The specified user is auto-disabled due to <num days> of inactivity. Administrator action is required to unlock.