The following list provides the alarms and events defined for the Resouce Manager. 


ID

Sub-ID

Type

MIB Trap  NameOID

Condition

Category

Decode Key

Default Severity

Auto Clear

Notes/Description

2

1

Alarm

uxAlmInvalidCardIDEEPROMData1.3.6.1.4.1.177.15.2.131073

Invalid Card ID EEPROM Data

Equipment

System;Card;PodName;ContainerType

Critical


  • A Card was detected with invalid Card ID EEPROM (failed CRC-CCITT check).
  • Suggested action - provide the entire alarm message including the numbers at the end to Ribbon Service for further assistance.

2

2

Alarm

uxAlmCardHealthCheckFailed1.3.6.1.4.1.177.15.2.131074

Card Health Check Failed

Equipment

System;Card;PodName;ContainerType

Critical


  • During Line Card activation, a Card Fault was detected after power was applied to the card.
  • The Card will remain out-of-service.
  • Suggested action - reboot system.
  • If issue persists, contact Ribbon Service with the alarm information.

2

3

Alarm

uxAlmCardnotSupported1.3.6.1.4.1.177.15.2.131075

Card not Supported

Equipment

System;Card;PodName;ContainerType

Major


  • A Card was detected which can be identified, but the SBC Edge software is unable to support.
  • The Card will remain out-of-service.
  • Suggested action - reboot system.
  • If issue persists, contact Ribbon Service with the alarm information.

2

4

Alarm

uxAlmPowerSupplyinputfailure1.3.6.1.4.1.177.15.2.131076

Power Supply input failure

Equipment

System;PSU;PodName;ContainerType

Major

(tick)

  • A Power supply module has indicated a failure of input power.
  • The SBC Edge has lost Power Supply redundancy.
  • Suggested action - Verify that the power cable is connected and that the PS is functioning properly.

2

5

Event

uxAlmPowerSupplyinputrestored1.3.6.1.4.1.177.15.2.131077

Power Supply input restored

Equipment

System;PSU;PodName;ContainerType



  • A Power Supply module has indicated that input power has been restored.
  • This event clears the "Power Supply Input Failure" Alarm.

2

6

Alarm

uxAlmPowerSupplyoutputfailure1.3.6.1.4.1.177.15.2.131078

Power Supply output failure

Equipment

System;PSU;PodName;ContainerType

Major


  • A Power Supply module has indicated a failure of output power.
  • The SBC Edge has lost Power Supply redundancy.
  • Suggested action - Verify that the PS is functioning properly.

2

7

Alarm

uxAlmSingleFanfailure1.3.6.1.4.1.177.15.2.131079

Single Fan failure

Equipment

System;Fan;PodName;ContainerType

Major


  • Check the System tab to find the Fan ID of the failed fan.
  • Contact Ribbon Service with this information.

2

8

Alarm

uxAlmMultipleFanFailures1.3.6.1.4.1.177.15.2.131080

Multiple Fan Failures

Equipment

System;Fans;PodName;ContainerType

Critical


  • Check the System tab to find the Fan ID's of the failed fans.
  • Contact Ribbon Service with this information.

2

9

Alarm

uxAlmSystemTemperatureWarm1.3.6.1.4.1.177.15.2.131081

System Temperature Warm

Equipment

System;PodName;ContainerType

Minor

(tick)

  • The temperature sensors have indicated that the system is running warm (55°C threshold).

2

10

Event

uxAlmSystemTemperatureWarmCleared1.3.6.1.4.1.177.15.2.131082

System Temperature Warm Cleared

Equipment

System;PodName;ContainerType



  • The temperature sensors have indicated that the system is no longer running warm (55°C threshold).
  • This event clears the 'System Temperature Warm' Alarm.

2

11

Alarm

uxAlmSystemTemperatureHot1.3.6.1.4.1.177.15.2.131083

System Temperature Hot

Equipment

System;PodName;ContainerType

Critical

(tick)

  • The temperature sensors have indicated that system is running hot (65°C threshold).

2

12

Event

uxAlmSystemTemperatureHotCleared1.3.6.1.4.1.177.15.2.131084

System Temperature Hot Cleared

Equipment

System;PodName;ContainerType



  • The temperature sensors have indicated that the system is no longer running hot (65°C threshold).
  • This event clears the 'System Temperature Hot' Alarm.
  • No labels