Working with Message Rule Tables

The SBC Edge Portfolio allows a maximum of 100 SIP Message Rule Tables and a maximum of 32 SIP Message rules per table. The maximum of 32 SIP Message rules per table includes all SIP rule types: Header, Request, Status, and Raw.

  1. In the WebUI, click the Settings tab.
  2. In the left navigation pane, go to SIP > Message Manipulation > Message Rule Table.



To view a table entry's properties:

  1. Click the pop-up icon () next to the entry you want to view.
  2. When you are finished, close the window.

To delete an entry, select the checkbox next to the entry and then click the Delete () icon.

To modify a Message Rule Table:

  1. Click the expand () Icon next to the entry you wish to modify.
  2. Modify the table's Description as desired
  3. Click OK.

To create a Message Rule Table:

  1. Click the Create Message Rule Table ( ) icon.

Message Rule Table Entry - Field Definitions

Applicable Messages


Specifies the message types for which this message table is applicable. For the Selected List option the Message Type List must be provided.

Message Selection

A list of message types to which this table applies. Maximum 20 Message Types. Visible only when Selected Message is chosen from the Applicable Message list box.

Table Result Type

Specifies whether failure of this Message Table causes subsequent Message Tables configured for a given Signaling Group to terminate or not. Optional means subsequent Message Tables will be applied, Mandatory means they will not.




  • No labels