About this Resource

Defines a CAS FXO Signaling Profile to be used in a CAS Signaling Group

REST API Methods for this Resource

Resource Schema

Configuration

Parameter Name Required Service Affecting Data Type Default Value Possible Values Description
DescriptionNoNostringnone64 - Max Length A description of the profile.
FxoLineTypeYesNoEnum1Possible values:
  • 0 - eCas_Analog
  • 1 - eCas_Digital
Used to decide if this Loop Start FXO profile is applied to analog or digital. Not currently supported.
OrientationYesNoEnum0Possible values:
  • 0 - eCas_User
  • 1 - eCas_Network
Set the CAS signaling orientation to FXO. Not currently supported.
LoopStartTypeYesYesEnum2Possible values:
  • 0 - eCas_LoopStartBasic
  • 1 - eCas_LoopStartReverseBattery
  • 2 - eCas_LoopStartForwardDisconnect
Set the Signaling Type for this Loop Start protocol.
DTMFOnTimeYesNoint100Possible values:
  • 45 - Minimum
  • 250 - Maximum
Used to set how long DTMF tones are on. The value specifies the time in milliseconds.
DTMFOffTimeYesNoint100Possible values:
  • 45 - Minimum
  • 250 - Maximum
Used to set how long DTMF tones are off. The value specifies the time in milliseconds.
MinimumForwardDisconnectDurationYesNoint700Possible values:
  • 100 - Minimum
  • 3000 - Maximum
Used to set the time that qualifies a valid forward disconnect (battery removal) that the system will accept. The value specifies the time in milliseconds. This parameter is valid only when Loop Start Type is set to "Forward Disconnect".
DialDelayYesNoint1000Possible values:
  • 0 - Minimum
  • 10000 - Maximum
Used to delay sending digits after going off-hook. The value specifies the time in milliseconds.
SilenceBasedDisconnectYesNoint3600Possible values:
  • 0 - Minimum
  • 3600 - Maximum
Used to enable/disable supervision that disconnects a VoIP call following silence for the length of time defined. The value specifies the time in seconds. The default of 0 disables this feature.
SilenceDetectionLevelNoNoint-38Possible values:
  • -38 - Minimum
  • -20 - Maximum
Used to configure the signal strength, in dBm, used for silence detection.
DialToneDetectYesNoEnum1Possible values:
  • 0 - btFalse
  • 1 - btTrue
Used to set if Loop Start should detect dial tone on the line before dialing out. Set to "true" to enable or "false" to disable.
ProvideToneWithAnswerYesNoEnum1Possible values:
  • 0 - btFalse
  • 1 - btTrue
Used to set if for inbound FXO calls that fail before connect, the system should attempt to Connect and play Fast Busy for a bit before Disconnecting the call. Set to "true" to enable or "false" to disable.
DisconnectSupervisionYesNoEnum0Possible values:
  • 0 - btFalse
  • 1 - btTrue
Used to enable/disable disconnect supervision of the CAS line. This parameter is valid only when Loop Start Type is set to "Basic".
DisconnectSupervisionOptionsYesNoint2Possible values:
  • 1 - Minimum
  • 5 - Maximum
Used to set the desired on/off cadence time in one cycle for disconnect tone detection. The value specifies the number of on-off intervals per cadence cycle. This parameter is valid only when Disconnect Supervision is set to "true".