This section specifies the Sustained Call Rate Utilization signaling quality measurement.

To View and Edit Qoe - Scru

On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Trunk Group > H323Trunk Group > H323 Trunk Advanced > Qoe > Scru. The Scru window is displayed.

The Qoe - Scru can be checked for each Address Context, for each Zone, for each H323Trunk Group created or for all the Address Contexts, Zones and H323Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone and H323Trunk Group.

The Edit Scru window is displayed.

H323 Trunk Advanced - Qoe - Scru Edit Window

The following fields are displayed:

H323 Trunk Advanced - Qoe - Scru Parameters


Parameter


Description

Critical Qos Scru LimitSpecifies the critical Sustained Call Rate Utilization (SCRU) limit, below which the call admission should be stopped. The value range from 80 - 100 and the default value is 80.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 