Use the Call Parameter Filter Profile window to configure profiles containing one or more sets of profile data that are used to query the local stored Active Directory (AD) data. The Call Parameter Filter Profile Data objects within a profile specify call parameter conditions for retrieving AD attributes. If a profile contains more than one condition, all conditions must be satisfied to match (AND operation). The AD attributes retrieved can be used in number manipulation, call routing, and policy processing. Refer to Flexible AD Support for ERE for more information on configuring the SBC to to retrieve and store subscriber data from an Active Directory (AD) server. 

To View Call Parameter Filter Profiles

On the SBC main screen, go to Configuration > Profile Management > Category: Call Parameter Filter Profile > Call Parameter Filter Profile or
All > ProfilesCall Parameter Filter Profile

The Call Parameter Filter Profile window opens.

Call Parameter Filter Profile

To Create a Call Parameter Filter Profile

To create a new Call Parameter Filter Profile:

  1. Click New Call Parameter Filter Profile. The Create New Call Parameter Filter Profile window opens.

    Create New Call Parameter Filter Profile

  2. Use the following table to specify general parameters for the profile and to define the first condition for the profile in the Call Parameter Filter Profile Data section. 

    Call Parameter Filter Profile Parameters

    ParameterDescription
    NameName for the profile
    DescriptionDescription of the profile
    Call Parameter Filter Profile Data
    Sequence IDSequence ID for the profile data object
    TypeProfile type. The default type and only option is AD (Active Directory)
    Ad AttributesAd attribute to use in defining the condition specified by the Call Parameter Filter Profile Data object. The Ad attributes from which you can select (Ad Attribute1 to Ad Attribute32) are mapped to specific Active Directory attributes in the Ad Attribute Map Profile.
    OperationOperation to use in the condition. Options are: =, <=, =/=, >=, Exist, Not Exist
    Ad CpeCall parameter element to use in the condition. Options are: Called Number, Called URI, Calling Name, Calling Number, Calling URI, Original Called Number, Original Calling Number, Redirecting Number, Redirection Number

  3. Click Save. To create additional Call Parameter Filter Profile Data objects within the profile, go to Call Parameter Filter Profile - Call Parameter Filter Profile Data.

Edit a Call Parameter Filter Profile

Once created, you can only edit the description of an existing Call Parameter Filter Profile. To change the Call Parameter Filter Profile Data in a profile, go to Call Parameter Filter Profile - Call Parameter Filter Profile Data.

 To edit an existing Call Parameter Filter Profile:

  1. Click the radio button next to the specific Call Parameter Filter Profile name. The Edit Selected Call Parameter Filter Profile window opens.
  2. Make the required changes and click Save.

To Copy a Call Parameter Filter Profile

To copy a Call Parameter Filter Profile: 

  1. Click the radio button next to the Call Parameter Filter Profile you want to copy.
  2. Click Copy Call Parameter Filter ProfileThe Copy Selected Call Parameter Filter Profile window opens.
  3. Make any required changes and click Save.

To Delete a Call Parameter Filter Profile

To delete a Call Parameter Filter Profile: 

  1. Click the radio button next to the Call Parameter Filter Profile you want to delete.
  2. Click the delete icon (X) at the end of the row. 
  3. Confirm the deletion when prompted.


  • No labels