Type: MAJOR 

Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.9

Description

This alarm indicates that the specified trunk group's configured maximum registration limit is reached due to one of the following conditions:

  • Number of registrations received on the ingress leg exceeds the configured limit
  • Number of implicit/child registrations received on the ingress leg exceeds the configured limit

Repetition

None

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusSipTgName

Instance Fields

sonusSipTgName

Action

None

Impact

None

Clearing

Manual

Note

The maximum number of registrations allowed is user-configurable.

  • No labels