Type: CRITICAL

Object ID1.3.6.1.4.1.2879.2.10.1.1.14.0.25
DescriptionThis alarm indicates that for a licensed feature, the session limit is reached. The service is denied for the affected call. This alarm is raised for each licensed feature for which the session limit is reached. However, the rate of the alarmed being triggered is limited to one alarm per license per minute.
RepetitionEvery minute.
Event Codes
  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusAlarmName
  • sonusActiveSessionCount
Instance Fields
  • sonusAlarmName
  • sonusActiveSessionCount
ActionConsider if more licenses should be ordered for the affected service.
ImpactThe specified service license reaches its limit and the SBC denies the associated service for the affected call. The SBC continues to deny any all further requests for the service, till the license is available.
ClearingManual

  • No labels