Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.13.0.2

Description

This alarm indicates that a Call Signaling Link to a Remote Gateway has closed.

Repetition

None

Event Codes

  • sonusGwRemoteGwAddr
  • sonusGwCloseReasonCode - Reason for close of Call Signaling Link:
    • administratorInitiatedClose(1)
    • closeRequestReceivedFromRemote(2)
    • remoteNotResponding(3)
    • internalError(4)
    • configError(5)
    • recvCallSigReqFromUnknownGw(6)
    • socketErrNetworkDown(7)
    • socketErrNetworkUnreachable(8)
    • socketErrNetworkReset(9)
    • socketErrSoftwareConnectionAbort(10)
    • socketErrConnectionResetByPeer(11)
    • socketErrNoBufferSpaceAvail(12)
    • socketErrAlreadyConnected(13)
    • socketErrNotConnected(14)
    • socketErrCantSendAfterShutdown(15)
    • socketErrTooManyReferences(16)
    • socketErrConnectionTimedOut(17)
    • socketErrUnknown(18)
    • recvDuplicateLinkOpenReq(19)
    • socketErrExceptionEvent(20)
    • linkXmtCongestion(21)
    • openNackReceivedFromRemote(22)
    • idleTimeOut(23)

Instance Fields

None

Action

None

Impact

None

Clearing

Automatic, sonusSbxGwSigChanOpenNotification

  • No labels