Object ID | 1.3.6.1.4.1.2879.2.10.1.1.13.0.2 |
Description | This alarm indicates that a Call Signaling Link to a Remote Gateway has closed. |
Repetition | None |
Event Codes | - sonusGwRemoteGwAddr
- sonusGwCloseReasonCode - Reason for close of Call Signaling Link:
- administratorInitiatedClose(1)
- closeRequestReceivedFromRemote(2)
- remoteNotResponding(3)
- internalError(4)
- configError(5)
- recvCallSigReqFromUnknownGw(6)
- socketErrNetworkDown(7)
- socketErrNetworkUnreachable(8)
- socketErrNetworkReset(9)
- socketErrSoftwareConnectionAbort(10)
- socketErrConnectionResetByPeer(11)
- socketErrNoBufferSpaceAvail(12)
- socketErrAlreadyConnected(13)
- socketErrNotConnected(14)
- socketErrCantSendAfterShutdown(15)
- socketErrTooManyReferences(16)
- socketErrConnectionTimedOut(17)
- socketErrUnknown(18)
- recvDuplicateLinkOpenReq(19)
- socketErrExceptionEvent(20)
- linkXmtCongestion(21)
- openNackReceivedFromRemote(22)
- idleTimeOut(23)
|
Instance Fields | None |
Action | System will automatically attempt to reopen the Call Signaling link. If attempts to re-open it continue to fail, verify if there are any network issues and address them. |
Impact | Functionality is impacted until the Call Signaling link opens. |
Clearing | Automatic, sonusSbxGwSigChanOpenNotification |