Type: CRITICAL

Object ID1.3.6.1.4.1.2879.2.10.1.1.14.0.29

Description

This trap is generated when either pass-through or transcoded sessions fail to setup due to the lack of a valid slb session license or if the total number of active slb sessions has reached the slb session license limits thereby unable to complete newer calls.

Repetition

None

Event Codes

  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription

Instance Fields

sonusSessLicenseLimit

Action

None

Impact

Call failures due to slb sessions license unavailability

Clearing

Manual

 

 