In this section:
The following table lists system naming conventions to follow while setting up SBC Core systems. The system name is used in billing, external PSX queries (if applicable), and system logs. On a HA system, the one system name applies to both units. Each unit has its own hostname as described in the next table. An example system name is WFDSBC01, where: Convention/Character The following table lists local and peer hostname conventions to follow while setting up SBC systems. The SBC hostname consists of the system name with additional characters appended to the system name to distinguish the hostname from the system name. For an HA system, the local hostname, peer hostname and system name must each be unique. For example, an HA system configured with a system name of “WFDSBC01” has the local hostname and peer hostname named “WFDSBC01a” and “WFDSBC01b”, respectively. Hostname is also referred to as "ceName". For example, "local ceName" and "peer ceName" are the equivalent of "local hostname" and "peer hostname". Convention/Character (1) The period is typically used to specify a fully qualified domain name. (2) The underscore character ‘_’ is not allowed in either the local hostname or peer hostname because it is not valid for SIP URI and TCP/IP host naming. One method to view the hostnames is to use the 'System Naming Conventions
System Name Use as Leading Character Use as Trailing Character Maximum number of characters 26 N/A N/A Letters [ a-z ] | [ A-Z ] Digits [ 0-9 ] Hyphen [ - ] Period [ . ] Underscore [ _ ] Other special characters Hostname Naming Conventions
Hostname/Peer Hostname Use as Leading Character Use as Trailing Character Maximum number of characters 64 N/A N/A Letters [ a-z ] | [ A-Z ] Digits [ 0-9 ] Hyphen [ - ] Period [ . ]1 Underscore [ _ ]2 Other special characters Viewing Local Hostname and and Peer Hostname From CLI
show table system serverStatus
' CLI command as shown in the example below where the hostnames are listed in the NAME column.admin@MYSBC-B> show table system serverStatus
MGMT LAST DAUGHTER
PLATFORM APPLICATION REDUNDANCY APPLICATION UP RESTART BOARD
NAME HW TYPE SERIAL NUM PART NUM VERSION VERSION ROLE UP TIME TIME REASON SYNC STATUS PRESENT
-----------------------------------------------------------------------------------------------------------------------------------------------------------
MYSBC-A SBC 5210 4049120002 821-00430 V06.02.00R000 V06.02.00R000 standby 87 Days 22:45:11 10 Days 22:39:50 switchover syncCompleted true
MYSBC-B SBC 5210 4047120359 821-00430 V06.02.00R000 V06.02.00R000 active 88 Days 00:32:37 27 Days 19:49:49 switchover syncCompleted true