Description | This alarm indicates that a Control Channel Link to a Remote D-SBC is closed. |
Repetition | This alarm occurs each time the D-SBC control channel is closed. The data includes the remote IP and port. |
Event Codes | sonusAlarmNodeID sonusAlarmLevel sonusAlarmSequenceId sonusAlarmTime sonusAlarmDescription sonusDsbcRemoteDsbcAddr sonusDsbcCloseReasonCode: Reason for the closure of the Control Channel Link - administratorInitiatedClose(1)
- closeRequestReceivedFromRemote(2)
- remoteNotResponding(3)
- internalError(4)
- configError(5)
- recvCallSigReqFromUnknownGw(6)
- socketErrNetworkDown(7)
- socketErrNetworkUnreachable(8)
- socketErrNetworkReset(9)
- socketErrSoftwareConnectionAbort(10)
- socketErrConnectionResetByPeer(11)
- socketErrNoBufferSpaceAvail(12)
- socketErrAlreadyConnected(13)
- socketErrNotConnected(14)
- socketErrCantSendAfterShutdown(15)
- socketErrTooManyReferences(16)
- socketErrConnectionTimedOut(17)
- socketErrUnknown(18)
- recvDuplicateLinkOpenReq(19)
- socketErrExceptionEvent(20)
- linkXmtCongestion(21)
- openNackReceivedFromRemote(22)
- idleTimeOut(23)
|
Instance Fields | sonusDsbcRemoteDsbcAddr sonusDsbcCloseReasonCode |
Action | Check connectivity for any link issues. |
Impact | May impact calls if the Control Channel link is not established. |
Clearing | Manual |