This object allows you to configure signaling timers for the node.
To View and Edit H323 Sig Timers
On SBC main screen, go to Configuration > Profile Management > Category: Signaling Timers > H323 Sig Timers.
The H323 Sig Timers window is displayed.
Profile Management - Signaling Timers - H323 Sig Timers
The following fields are displayed:
H323Sig Timers Parameters
Parameter | Description |
---|
Establish | Specifies the H225 signal channel establishment timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 4 seconds. |
Tcp Connect | Specifies the TCP connect timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 3 seconds. |
T301 | Specifies the T301 call timer (in seconds). The value ranges from 0 to 65535 seconds and the default value is 180 seconds. |
T302 | Specifies the T302 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 15 seconds. |
T303 | Specifies the T303 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 4 seconds. |
T304 | Specifies the T304 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 20 seconds. |
T310 | Specifies the T310 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 10 seconds. |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.