Specifies the MFR2 digit generation attributes.
To View and Edit Mfr2Generate
On the SBC main screen, go to Configuration > Profile Management > Category: Digit Profiles > Digit Profiles > Mfr2Generate.
Select the desired Digit Profile from the drop-down list to view its respective Mfr2Generate parameters.
The Mfr2Generate window is displayed.
Profile Management - Digit Profiles - Mfr2Generate
The following fields are displayed:
Dtmf Mfr2Generate Parameters
Parameter | Description |
---|
Power | Digit generation power level (in dBm). (range: -50 to +3 / default = -7). |
Make | Duration (in milliseconds) of generated digits. (range: 0-8000 / default = 150). |
Break | Silence duration (in milliseconds) between generated digits (range: 0-8000 / default = 150). |
Pre Pulse Delay | Delay (in milliseconds) between the end of last compelled signal and the start of backward pulsed signal. (range: 0-8000 / default = 100). |
Max Fwd On Duration | Maximum amount of time (in milliseconds) a forward signal is sent. (range: 100-60000 / default = 15000). |
Max Fwd Off Duration | Maximum amount of time (in milliseconds) between the removal of a forward signal and the sending of the next forward signal. (range: 100-60000 / default = 27000). |
Final Digit Delay | Minimum interval (in milliseconds) after sending last message to apply answer line signal in the backward direction. (range: 0-8000 / default = 50). |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.