This objects defines the parameters controlling registration relay behavior.

To View and Edit Registration

On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Trunk Group > Sip Trunk Group > Signaling > Registration. The Registration window is displayed.

The Registration can be checked for each Address Context, for each Zone, for each Sip Trunk Group created or for all the Address Contexts, Zones and Sip Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone and Sip Trunk Group.

The Edit Registration window is displayed.

Sip Trunk Group - Signaling - Registration

 

 

The following fields are displayed:

Sip Trunk Group - Signaling - Registration

 

Parameter

Description

Require Registration

 Use this flag to specify the type of endpoint   registration validation required. 

  • None – (default) No registration validation is   required. 
  • Required –  Prevent unregistered IADs from making or receiving any calls. 
  • Required-nonpriority – Prevent unregistered IADs from making or receiving non-priority   calls. Since priority calls are exempt, unregistered endpoints are still allowed to make priority calls. 
  • Supported –   Accept registrations from unregistered endpoints when the associated trunk   group is used for endpoints optionally requiring registration. If an endpoint   is registered, then the registration data is used to send calls to that   endpoint instead of PSX route. 
  • Supported-group   – Accept registrations from unregistered users and from users whose user   names do not match with the stored URI in Registration Control Block. If an   endpoint is registered, then the registration data is used to send calls to   that endpoint instead of PSX route.

  • Required-group  – If this option is selected for an ingress IP trunk group in relation to a received call (e.g. call from IP-PBX towards AS) so that if the source IP address and port of the INVITE/OOD request do not match the source IP address and port of an existing registration in the zone, they are rejected. However, if the AOR does not match, but if the source IP Address and the port match to the existing registration in the zone, messages are accepted. If this option is selected for an egress IP trunk group in relation to a received call (e.g. call from AS towards IP-PBX), the user part check between registered AoR and Request-URI of the INVITE does not occur, and the call is accepted.
  • Required-group-nonpriority – Use this option to prevent unregistered IADs from making or receiving non-priority calls. All emergency calls are allowed even if the source IP/port fails to fetch RCB.

Set Require Registration flag to ‘supported-group’ for the IP Peer on which surrogate registration functionality is being enabled.

In loopback scenarios for SIP-H323 calls, Require Registration must be set to none.

Expires

 The time (in seconds) a SIP endpoint's registration session lasts before requiring re-registration. This value does not apply if the endpoint is NAT'd. The value ranges from 15 to 65535 and the default value is 3600.

Inside Expires Minimum

 Controls the initial expire value (in seconds)   in a REGISTER relayed to a registrar. The value ranges from 0 to 65535 and the default value is 3600.

  1. Since the SBC expects an expires value greater than 540 seconds (9 minutes) from the registrar, do not set “insideExpiresMinimum” value less than 540 seconds. Ideally, set this value much higher (3600 seconds is recommended) to avoid overloading registrar with register refreshes.
  2. When configuring surrogate registration, be sure to set the expires value of ingress trunk group toward IAD to the maximum default value of “3600”.

Include XOriginal Addr

 Enable this flag to insert the X Original Addr header into REGISTER message. 

  • Disabled (default) 
  • Enabled

Bulk Register Format

 Use this flag to determine how the   registration requests are formatted with respect to RFC 6140. 

  • Disabled (default) – REGISTER message is not formatted as per RFC 6140. 
  • Enabled – REGISTER message is formatted as per RFC 6140. 
  • Follow Ingress – No changes are made to the Egress Register with respect to RFC 6140.
Int Refresh Factor MinDefines the minimum factor for random number calculation for internal refresh timeout. The range values from 0 to 1000 and the default value is 0.
Int Refresh Factor Max

Defines the maximum factor for random number calculation for internal refresh timeout. The range values from 0 to 1000 and the default value is 0.

If "Int Refresh Factor Max" is less than "Int Refresh Factor Min" or both "Int Refresh Factor Max" and "Int Refresh Factor Min" are set to 0, the random factors are ignored and the timeouts or the deadlines are calculated using a random number between x and x/2.

Ext Refresh Factor MinDefines the minimum factor for random number calculation for external refresh timeout. The range values from 0 to 1000 and the default value is 0.
Ext Refresh Factor Max

Defines the maximum factor for random number calculation for external refresh timeout. The range values from 0 to 1000 and the default value is 0.

If "Ext Refresh Factor Max" is less than "Ext Refresh Factor Min" or both "Ext Refresh Factor Max" and "Ext Refresh Factor Min" are set to 0, the random factors are ignored and the timeouts or the deadlines are calculated using a random number between x and x/2.

Always Random Int Expires

If enabled, the internal expire timeout will be randomized for the initial and the refresh REGISTER.

If disabled, the internal expire timeout will be randomized for the initial REGISTER.

The options are:

  • Disabled (default)
  • Enabled
Always Random Ext Expires

If enabled, the external expire timeout will be randomized for the initial and the refresh REGISTER.

If disabled, the external expire timeout will be randomized for the initial REGISTER.

The options are:

  • Disabled (default)
  • Enabled
Use RUri For Register Routing

If disabled, Global Loop Detection flag takes precedence.

If enabled, Loop Detection is disabled, irrespective of Global Loop Detection flag.

The options are:

  • Disabled (default)
  • Enabled

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 

  • No labels