Type: MINOR 

Object ID 1.3.6.1.4.1.2879.2.10.1.3.1.0.16

Description

This trap indicates that an Address of Record (AOR) registering from multiple contact addresses is reusing a signaling port towards the registrar. This trap is generated once per zone.

Repetition

None

Objects

  • sonusSipAorSigZoneId
  • sonusAlarmNodeName
  • sonusAlarmPodName
  • sonusAlarmContainerName
  • sonusAlarmNsUuid
  • sonusAlarmCnfUuid
  • sonusAlarmCnfcUuid

Action

Ensure enough signaling ports are allocated in the Zone.

Impact

Calls are not routed towards the AOR registered prior to this registration unless the registrar supports reg-info parameter.

Clearing

Manual