Object ID | 1.3.6.1.4.1.2879.2.10.1.1.4.0.5 |
Description | This trap indicates that for a given emergency call the SBC is unable to route the call on any of the provided routes. This is a warning indicator of a failed emergency call. |
Repetition | None |
Objects | - sonusActiveCallIngressPstnTrunk—For calls originating from PSTN (circuit) side, specifies the Trunk Group name to which the Ingress PSTN channel belongs.
- sonusNodeResourceIsupCircuit—Base circuit identity code (CIC) for the circuit.
- sonusActiveCallCallingNum—The E.164 number representing the calling party's telephone number.
- sonusActiveCallCalledNum—The E.164 number representing the called party's telephone number.
- sonusActiveCallOrigCalledNum—If an address translation is performed on the called party number, this entry contains the original, untranslated number.
|
Action | Investigate why the calls are failing |
Impact | Emergency calls will not route |
Clearing | Manual |