Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.10.1.3.8.0.1 |
Description | The trap indicates the specified number of InformRequest PDUs destined to the specified Management Client were flushed from the InformRequest PDU queue because no Response PDUs were received from the Management Client. This situation can occur if the Management Client cannot quickly process and respond to InformRequest PDUs that it receives, or if communications is lost with the Management Client. |
Repetition | None |
Objects |
|
Action | If this situation occurs occasionally, it is recommended to increase the InformRequest PDU timeout and/or retry values (see sonusNetMgmtClientInformReqRspTimeout and sonusNetMgmtClientInformReqRetries.) If this situation occurs repeatedly, it is an indication that communication is lost with the Management Client, either because of network problems, or because the Management Client is no longer operational. It is recommended that this device be configured to send a alarm PDU, not an InformRequest PDU, for this Notification to all Management Clients, thus bypassing a problematic InformRequest PDU queue and allowing the situation to be quickly identified and resolved. |
Impact | None |
Clearing | Manual |