Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.4.1.1.0.2

Description

This alarm is generated when the SBC registers to a local PSX server.

Repetition

None

Objects

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusPolicyServerClientName
  • sonusPolicyServerRegisterReason
  • sonusAlarmNodeName
  • sonusAlarmPodName
  • sonusAlarmContainerName
  • sonusAlarmNsUuid
  • sonusAlarmCnfUuid
  • sonusAlarmCnfcUuid

Action

Refer to register reason in this alarm to see if any action is necessary.

Impact

Once registered, the SBC can place calls.

Clearing

Manual

This alarm is not generated when registering to an external PSX.