Type: INFORMATIONAL

Object ID1.3.6.1.4.1.2879.2.10.1.1.4.0.59

Description

This event is generated when the MRFP receives a trace activation request (through the H.248 TRACEACTIVITYREQUEST as part of the call trace package) from an MRFC and the MRFP initiates tracing.

Repetition

No

Objects

  • EVENT_MRFP_CALL_TRACE_STARTED_NOTIFICATION
  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription

Action

None

Impact

The MRFP receives a request for tracing (which has limited impact on capacity). Once the trace completes, an MrfpCallTraceConcludedSuccessNotification event sends.

Clearing

Manual