Type: INFORMATIONAL

Object ID1.3.6.1.4.1.2879.2.10.1.1.4.0.61

Description

This event is generated when the MRFP receives a trace activation request (through the H.248 TRACEACTIVITYREQUEST as part of the call trace package) from an MRFC and the MRFP cannot activate tracing.

Note: This event sends if the callTrace state is set to disabled (refer to Call Trace - CLI) and the MRFP receives a request to trace a termination.

Note: This event sends if the maximum number of traces is reached and the MRFP receives a request to trace a termination.

Repetition

If the MRFC sends multiple tracing requests during a context's lifetime (for example, a request sends on multiple terminations or mid-call in a MODIFY command), the MRFP can receive this event multiple times.

Objects

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmDescription
  • sonusAlarmTime

  • sonusContextID

Action

 Investigate based on the reason why the trace failed. For example, you must enable tracing if tracing was disabled through the configuration.

Impact

Tracing calls may not be possible (for example, the feature is disabled or the maximum number of contexts are reached).

Clearing

Manual