This is the global diameter profile containing elements that indicate whether Rf is enabled or not. The Diam Sig Controls profile contains the following elements:
On SBC main screen, go to All > Global > Signaling > Diam Sig Controls. The Diam Sig Controls window is displayed.
Figure 1: Global - Signaling - Diam Sig Controls
The following fields are displayed:
Table 1: Diam Sig Controls Parameters
Parameter | Description |
---|---|
Enable Rf App | This parameter indicates whether Rf is enabled system wide. Based on this parameter, only normal CDR can be stopped. The options are:
|
Default CCF | This parameter is used as CDF, if CCF is not received in the PCFA. By default, 0.0.0.0 is displayed. |
Rf Interim Acc Inrvl | This is over written if Accounting-Answer (ACA) has different value. 0 means no interim record is sent. The value ranges from 0 to 180 and the default value is 30. |
Generate Failed Event Acr | If this parameter is enabled, no Accounting-Request (ACR) event for failed call can be sent. The options are:
|
Max ACRetransmission | This parameter supports maximum number of retransmission of ACR, if SBC does not receive ACA. The value ranges from 0 to 3 and the default value is 0. |
Add Sonus Specific AVP | Enable flag to send additional CDR information within Sonus vendor-specific Attribute Value Pairs (AVPs) in Accounting-Request (ACR) messages over the existing Rf Interface.
See Rf Interface Support for AVP details. |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.