Use this screen to configure the signaling quality measurements for Call Limit Utilization (CLU). On the SBC main screen, go to Configuration > System Provisioning > Security Configuration > SIP CAC Profile > QOE > Clu. Select the desired SIP CAC Profile from the drop-down list to view its respective QOE - Clu parameters. The Clu window is displayed. Clu Parameters: The critical Call Limit Utilization (CLU) limit below which the call admission should stop. The default is 80. Make the required changes and click Save.To View and Edit Clu
Parameter Length/Range Description Clu Critical Limit 80-100