An Overload Profile specifies a set of congestion thresholds and congestion durations you can assign to a particular machine congestion (MC) level. When the "set" threshold for the profile assigned to a particular congestion level is exceeded for the "set" duration, the congestion level is raised to a higher level and overload controls are applied to help alleviate the congestion. The profile also specifies "clear" congestion thresholds and durations. The clear values specify the level to which congestion conditions must fall for the specified duration in order to return to the previous congestion level. These minimum clear durations prevent repeatedly switching in and out of congestion levels. You may assign Overload Profiles to the system (that apply throughout the SBC). The following default Overload Profiles are automatically assigned to define thresholds and duration to system congestion levels 1-3 (MC1, MC2, and MC3): In order to change its configuration, you must first disable an Overload Profile. Then, when you enable the profile, you cause all its parameter values to be validated. Once validated, these values are applied to the (system) congestion level to which you assign the profile. When you make a change in this manner, the system congestion level is cleared if the Overload Profile was being referenced. Standby modules also perform congestion processing but you cannot configure the module settings. On the SBC main screen, choose a path: The Overload Profile window is displayed. To enable or disable any of the Overload Profiles in the list, click the radio button next to the specific Overload Profile name. The Edit Selected Overload Profile window is displayed. Make the required change and click Save. Overload Profile Parameters: The Overload Profile name. This field is not editable. The administrative state of this Overload Profile. To create a new Overload Profile, click New Overload Profile on the Overload Profile List panel. The Create New Overload Profile window is displayed. Overload Profile Parameters: Overload Profile name. Use the following default profiles to create custom profiles: Administrative state of the Overload profile.To View Overload Profiles
To Enable or Disable Overload Profiles
Parameter Description Name State To Create an Overload Profile
Parameter Description Name State To Copy an Overload Profile
To Delete an Overload Profile
After you disable or create an Overload Profile object, you can use the following windows to set the specific values for set/clear thresholds and set/clear duration for the profile.