Use this screen to configure the signaling quality measurements for Call Limit Utilization (CLU).

To View and Edit Clu

On the SBC main screen, go to Configuration > System Provisioning > Security Configuration > SIP CAC Profile > QOE > Clu.

Select the desired SIP CAC Profile from the drop-down list to view its respective QOE - Clu parameters.

The Clu window is displayed.


Clu Parameters:

ParameterLength/RangeDescription
Clu Critical Limit80-100

The critical Call Limit Utilization (CLU) limit below which the call admission should stop.

The default is 80.

Make the required changes and click Save.