This window defines when to generate/clear an alarm for SRTP integrity failures. A Major alarm (sonusSystemSecurityMediaErrorNotification) is raised when the current SRTP integrity failure rate is above the Set Threshold value and clears (sonusSystemSecurityMediaErrClearNotification) once the error rate goes below the Clear Threshold value. Refer to the SBC Core Alarms Guide to know more about these two alarms (you can search for these alarms).

To View and Edit Media Srtp Err Alarm

On the SBC main screen, go to All > OAM > Alarm > Media Srtp Err Alarm. The Media Srtp Err Alarm window is displayed.

OAM - Media Srtp Err Alarm parameter

Parameter

Length/Range

Description

Set Threshold

0-2147483647

The threshold value to set this alarm. The default value is 1000.

A value of "0" disables the alarm.

Clear Threshold0-65535The threshold value to clear this alarm. The default value is 100.


Make the required changes and click Save.