In this section:
Use this screen to define criteria for applying DM/PM (digit manipulation/ parameter manipulation) rules. You can also use this screen to define criteria for applying URI manipulation rules. For digit manipulation, the matching criteria can be digits in the calling or called numbers, outpulse numbers from SCP queries, generic numbers, and so on. For example, you can provision the SBC 7000 to check if the first three digits of the calling number are 617, or to check if digits 4 through 6 are 723. For parameter manipulation, the matching criteria is based on the specified parameter type. For example, you can provision the SBC 5400 series to match a specified Calling Party Category (CPC), or match a specified Originating Line Information Parameter (OLIP) value. On the SBC main screen, go to Configuration > System Provisioning > Category: Call Routing > Profiles > Digit Parameter Handling > DM PM Criteria. The DM PM Criteria window is displayed. Call Routing - Digit Parameter Handling - DM PM Criteria To edit any of the DM/PM Criteria in the list, click the radio button next to the specific DM/PM Criteria name. The Edit Selected DM PM Criteria window is displayed below. Call Routing - Digit Parameter Handling - DM PM Criteria Edit Make the required changes and click Save. To create a new DM/PM Criteria, click New DM PM Criteria tab on the DM PM Criteria List panel. The Create New DM PM Criteria window is displayed. Call Routing - Digit Parameter Handling - DM PM Criteria Create Window DM/PM Criteria Parameters: Select the criteria type from the drop-down list: Digit Type The digit/parameter type to which this DM/PM Criteria entry applies. For digit manipulation, the possible choices are: Parameter Preference Check The SBC applies PM rules based on whether a parameter exists or does not exist. To copy any of the created DM/PM Criteria and to make any minor changes, click the radio button next to the specific DM/PM Criteria to highlight the row. Click Copy DM PM Criteria tab on the DM PM Criteria List panel. The Copy Selected DM PM Criteria window is displayed along with the field details which can be edited. Call Routing - Digit Parameter Handling - DM PM Criteria Copy Window Make the required changes to the required fields and click Save. The copied DM/PM Criteria is displayed at the bottom of the original DM/PM Criteria in the DM PM Criteria List panel. To delete any of the created DM/PM Criteria, click the radio button next to the specific DM/PM Criteria which you want to delete. Click Delete at the end of the highlighted row. A delete confirmation message appears seeking your decision. Click Yes to remove the specific DM/PM Criteria from the list.To View DM/PM Criteria
To Edit DM/PM Criteria
To Create DM/PM Criteria
Parameter Description Name The name of the DM/PM (digit manipulation/parameter manipulation), up to 23 characters. Criteria Type
• Exists—The SBC 5400 applies the associated PM rule if the parameter is present in the call parameters.
• Doesnt Exist—The SBC applies the associated PM rule if the parameter is not present in the call parameters.To Copy DM/PM Criteria
To Delete DM/PM Criteria