In this section:
The Visual First Call Setup configuration wizard is an EMA-based tool that guides you in configuring the SBC to process calls in a laboratory (non-production) environment under light to moderate levels of traffic.
Visual First Call Setup is not available for SBC Cloud environments.
Take note of the following while using a configuration wizard:
Avoid navigating to other EMA objects or windows while using this tool to avoid a disrupted workflow resulting in an out-of-sync configuration. Before navigating to the other EMA objects, complete and save the configuration element on which you are presently working. Once you save the Visual First Call Setup configuration, you can then navigate to and configure other EMA or CLI objects, but avoid creating objects that are related to the configuration in your saved configuration.
The Visual First Call Setup wizard does not include real-time updates of the configuration status of objects. If you configure an object using this tool, and then delete the configuration through EMA or CLI, the tool still reflects the configuration status as "configured" and displays the “Configuration Complete” green icon adjacent to the object rather than the expected red icon which indicates no configuration.
On the SBC main screen, navigate to Configuration > Configuration Wizards > Visual First Call Setup.
The banner Provision the SBC for Basic SIP Peering (at the top of the Visual First Call Setup window) displays information on the preliminaries of the configuration procedure.
There are two options to view the entire consolidated configuration:
View as Diagram
(default)View as Table
Diagram View | Table View |
By default, the Visual First Call Setup window is displayed as a diagram as illustrated in the figure Visual First Call Setup - View as Diagram.
To view the consolidated configuration in tabular form, select View as Table.
The gear icon is not displayed when the configuration is viewed as a table. The tabular presentation is suitable for viewing the configuration, but to configure the SBC using the Visual First Call Setup tool, switch to View as Diagram.
If the SBC is not configured using the Visual First Call Setup tool, as in case of a freshly installed/upgraded SBC:
When viewed as diagram, instead of a green circle, a red circle is displayed beside each configuration element. For more information, see Provision the SBC for Basic SIP Peering
With the exception of Customer Network > PBX and Carrier Network > Carrier, all other configuration elements remain inactive; this is to ensure that the sequence of the configuration is maintained.
When viewed as table, the table is displayed only with fields but no values.
During a Fresh Installation, you cannot update certain configurations before configuring their prerequisite. Follow the Configuration Elements Hierarchy to configure the elements displayed in the Visual First Call Setup window.
Customer Network
PBX
Carrier Network
Carrier
<CE Name>
Internal/Core/Trusted Side
IP Interface Group
IP Interface
Static Route
Zone
SIP Trunk Group
SIP Signaling Port
IP Peer
External/Carrier/Untrusted Side
IP Interface Group
IP Interface
Static Route
Zone
SIP Trunk Group
SIP Signaling Port
IP Peer
Routing
While configuring various elements of the Visual First Call Setup tool, you may encounter error messages of two types:
Port Name
as pkt0
(displayed on the Edit Media IP Interface window) for both Internal (PBX) as well as External (Carrier) side of the setup, an error message is generated from the back-end and displayed on your browser.